The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Guest-Induced Ultrasensitive Detection of Multiple Toxic Organics and Fe3+ Ions in a Strategically Designed and Regenerative Smart Fluorescent Metal–Organic Framework
Abstract
Luminescent metal–organic frameworks (LMOFs) are promising functional materials for sustainable applications, where an analyte-induced multiresponsive system with good recyclability is beneficial for detecting numerous lethal pollutants. We designed and built the dual-functionalized, three-dimensional Zn(II)–framework [Zn 3 ( bpg ) 1.5 ( azdc ) 3 ]·(DMF) 5.9 ·(H 2 O) 1.05 ( CSMCRI-1 ) using an −OH group-integrated bpg linker and a −N═N– moiety containing H 2 azdc ligand, which functions as a unique tetrasensoric fluorescent probe. The activated CSMCRI-1 ( 1′ ) represents the hitherto unreported pillar-layer framework for extremely selective fluorescence quenching by nitrofurazone antibiotics as well as explosive nitro-aromatic 2,4,6-trinitrophenol, where ultrasensitive detection is achieved for both the electron-lacking analytes. Impressively, 1′ represents the first ever MOF for significant fluorescence “turn-on” detection of toxic and electron-rich 4-aminophenol in the concurrent presence of isomeric analogues. Density functional theory calculations highlight the specific importance of pillar functionalization in the “turn-on” or “turn-off” responses of 1′ by electronically divergent toxic organics and provide further proof of supramolecular interactions between the framework and analytes. The fluorescence intensity of 1′ dramatically quenches by a trace amount of Fe 3+ ions over other competing metal ions, alongside visible colorimetric change of the framework in solid and solution phase upon Fe 3+ encapsulation. The sensing ability of 1′ remains unaltered for multiple cycles toward all lethal pollutants. The sensing mechanism is attributed to both dynamic and static quenching as well as resonance energy transfer, which strongly comply with the predictions of theoretical simulations. Considering the long-term and real-time monitoring, AND as well as OR molecular logic gates are constructed based on the discriminative fluorescence response for each analyte that provides a platform to fabricate smart LMOFs with multimode logic operations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hepcidin in the diagnosis of iron disorders
Girelli, D., Nemeth, E., & Swinkels, D. W. (2016) · Blood · doi:10.1182/blood-2015-12-639112 · Cited by 417
Cited by
Sensing organic analytes by metal–organic frameworks: a new way of considering the topic
Hu, M.-L., Razavi, S. A. A., Piroozzadeh, M., & Morsali, A. (2020) · Inorganic Chemistry Frontiers · doi:10.1039/c9qi01617a · Cited by 295
Metadata
- Authors
- Goswami, R., Mandal, S. C., Pathak, B., & Neogi, S.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-02-05
- Volume
- 11
- Issue
- 9
- Pages
- 9042-9053
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2914063037
- Cited by
- 220
- References
- 1
- FWCI
- 11.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Guest-Induced Ultrasensitive Detection of Multiple Toxic Organics and Fe3+ Ions in a Strategically Designed and Regenerative Smart Fluorescent Metal–Organic Framework. https://app.cochat.ai/papers/10.1021/acsami.8b20013
- The paper
- Goswami, R., Mandal, S. C., Pathak, B., & Neogi, S. (2019). Guest-Induced Ultrasensitive Detection of Multiple Toxic Organics and Fe3+ Ions in a Strategically Designed and Regenerative Smart Fluorescent Metal–Organic Framework. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.8b20013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.