The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Mechanical Strength, Biodegradation, and in Vitro and in Vivo Biocompatibility of Zn Biomaterials
Abstract
Zn-based biomaterials have emerged as promising new types of bioresorbable metallics applicable to orthopedic devices, cardiovascular stents, and other medical applications recently. Compared to other degradable metallic biomaterials (i.e., Mg- or Fe-based), Zn biomaterials have a more appropriate corrosion rate without hydrogen gas evolution. Here, we evaluated the potential of Zn-based metallics as medical implants, both in vitro and in vivo, alongside a standard benchmark Mg alloy, AZ31. The mechanical properties of the pure Zn were not strong enough but were significantly enhanced (microhardness > 70 kg/mm 2, strength > 220 MPa, elongation > 15%) after alloying with Sr or Mg (1.5 at. %), surpassing the minimal design criteria for load-bearing device applications. The corrosion rate of Zn-based biomaterials was about 0.4 mm/year, significantly slower than that of AZ31. The measured cell viability and proliferation of three different human primary cells fared better for Zn-based biomaterials than AZ31 using both direct and indirect culture methods. Platelet adhesion and activation on Zn-based materials were minimal, significantly less than on AZ31. The hemolysis ratio of red cells (<0.5%) after incubation with Zn-based materials was also well below the ISO standard of 5%. Moreover, Zn-based biomaterials promoted stem cell differentiation to induce the extracellular matrix mineralization process. In addition, in vivo animal testing using subcutaneous, bone, and vascular implantations revealed that the acute toxicity and immune response of Zn-based biomaterials were minimal/moderate, comparable to that of AZ31. No extensive cell death and foreign body reactions were observed. Taken together, Zn-based biomaterials may have a great potential as promising candidates for medical implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Long-term surveillance of zinc implant in murine artery: Surprisingly steady biocorrosion rate
Drelich, A. J., Zhao, S., Guillory, R. J., Drelich, J. W., & Goldman, J. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.05.045 · Cited by 188
Cited by
Kabir, H., Munir, K., Wen, C., & Li, Y. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.09.013 · Cited by 397
Additively manufactured biodegradable porous iron
Li, Y., Jahr, H., Lietaert, K., Pavanram, P., Yilmaz, A., Fockaert, L. I., Leeflang, M. A., Pouran, B., Gonzalez-Garcia, Y., Weinans, H., et al. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.07.011 · Cited by 299
Su, Y., Wang, K., Gao, J., Yang, Y., Qin, Y.-X., Zheng, Y., & Zhu, D. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.03.055 · Cited by 268
Self-citation
Metadata
- Authors
- Zhu, D., Cockerill, I., Su, Y., Zhang, Z., Fu, J., Lee, K.-W., Ma, J., Okpokwasili, C., Tang, L., Zheng, Y., Qin, Y.-X., & Wang, Y.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-01-29
- Volume
- 11
- Issue
- 7
- Pages
- 6809-6819
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2911472734
- Cited by
- 202
- References
- 1
- FWCI
- 5.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.