The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In Situ Synthesis of a Sandwich-like Graphene@ZIF-67 Heterostructure for Highly Sensitive Nonenzymatic Glucose Sensing in Human Serums
Abstract
Metal–organic frameworks (MOFs) have been extensively studied in recent years due to their tunable porosity, huge specific area, and controllable structure. The rich metal centers and large specific area have endowed MOFs with excellent electrochemical activity due to the multiple valence states, but the poor electronic conductivity of MOFs seriously impedes their electrocatalytic performance. Here, a polyhedral Co-based zeolite imidazole frame [Co(mim) 2 ] n (denoted as ZIF-67, mim = 2-methylimidazole) is in situ loaded on the two sides of physically exfoliated graphene nanosheets (GSs) at room temperature, and sandwich-like GS@ZIF-67 hybrids with an ordered nanostructure are easily obtained. Compared with each individual component, the as-synthesized GS@ZIF-67 hybrids exhibit higher electrochemical activity toward glucose oxidation. Besides, the hierarchical nanocomposites also show better electrocatalytic performance compared with the same ratio of a physical mixture of GSs and ZIF-67, further demonstrating the synergistic effect between ZIF-67 and GSs. Thus, a highly sensitive nonenzymatic glucose electrochemical sensor is proposed with a linear range of 1–805.5 μM, sensitivity of 1521.1 μA Mm –1 cm –2, detection limit of 0.36 μM (S/N = 3), and excellent stability and selectivity. More importantly, the newly fabricated sensor is also successfully applied for glucose determination in human serums with satisfactory results, suggesting its promising potential toward glucose detection in real samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Cited by
Metal-organic framework-based materials as an emerging platform for advanced electrochemical sensing
Liu, C.-S., Li, J., & Pang, H. (2020) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213222 · Cited by 484
Zhang, L., Cai, P., Wei, Z., Liu, T., Yu, J., Al-Ghamdi, A. A., & Wageh, S. (2021) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2020.11.056 · Cited by 261
Flexible Plasmonic Biosensors for Healthcare Monitoring: Progress and Prospects
Song, L., Chen, J., Xu, B. B., & Huang, Y. (2021) · ACS Nano · doi:10.1021/acsnano.1c07176 · Cited by 186
Li, G., & Wen, D. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02474c · Cited by 119
Metadata
- Authors
- Chen, X., Liu, D., Cao, G., Tang, Y., & Wu, C.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-02-07
- Volume
- 11
- Issue
- 9
- Pages
- 9374-9384
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2912697097
- Cited by
- 185
- References
- 1
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.