The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High-Strength, Self-Healable, Temperature-Sensitive, MXene-Containing Composite Hydrogel as a Smart Compression Sensor
Abstract
As a new two-dimensional material similar to graphene, MXene has attracted extensive attention in the field of electrochemical materials such as supercapacitors because of its excellent mechanical properties, electrical conductivity, and thermal conductivity. What is better than graphene is that the few-layer MXene material obtained by proper treatment has good water dispersibility and can be used as an ideal nanomaterial to enhance the conductivity of hydrogels. However, the articles about the few-layer MXene material used in the preparation of composite hydrogels are rare. In this paper, MXene was synthesized by Yury mild method. Poly( N -isopropyl acrylamide) (PNIPAM) hydrogel and physical cross-linking hydrogel were used as the matrix to prepare composite hydrogels with temperature sensitivity and stress-sensing properties. The composite hydrogels exhibited excellent mechanical properties: it could be stretched to over 14 times the original length and achieved a 0.4 MPa tensile strength while showing good self-healing ability, which was of great significance for the practical application of hydrogels. The conductivity of the composite hydrogel was 1.092 S/m, which was about 15 times that of the control hydrogel without MXene. The potential of the composite hydrogel as a smart compression sensor was also verified by the conductivity tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carbon-Nanotube-Embedded Hydrogel Sheets for Engineering Cardiac Constructs and Bioactuators
Shin, S. R., Jung, S. M., Zalabany, M., Kim, K., Zorlutuna, P., Kim, S. B., Nikkhah, M., Khabiry, M., Azize, M., Kong, J., et al. (2013) · ACS Nano · doi:10.1021/nn305559j · Cited by 946
Cited by
El-Husseiny, H. M., Mady, E. A., Hamabe, L., Abugomaa, A., Shimada, K., Yoshida, T., Tanaka, T., Yokoi, A., Elbadawy, M., & Tanaka, R. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2021.100186 · Cited by 533
Zhao, Z., Xia, K., Hou, Y., Zhang, Q., Ye, Z., & Lu, J. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00800e · Cited by 490
2D Transition Metal Carbides (MXenes): Applications as an Electrically Conducting Material
Shahzad, F., Iqbal, A., Kim, H., & Koo, C. M. (2020) · Advanced Materials · doi:10.1002/adma.202002159 · Cited by 451
Nanocomposite hydrogel-based strain and pressure sensors: a review
Sun, X., Yao, F., & Li, J. (2020) · Journal of Materials Chemistry A · doi:10.1039/d0ta06965e · Cited by 420
Ti3C2Tx MXene-Based Flexible Piezoresistive Physical Sensors
Wang, Y., Yue, Y., Cheng, F., Cheng, Y., Ge, B., Liu, N., & Gao, Y. (2022) · ACS Nano · doi:10.1021/acsnano.1c09925 · Cited by 406
Metadata
- Authors
- Zhang, Y., Chen, K., Li, Y., Lan, J., Yan, B., Shi, L., & Ran, R.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-11-20
- Volume
- 11
- Issue
- 50
- Pages
- 47350-47357
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2990952977
- Cited by
- 220
- References
- 1
- FWCI
- 9.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.