The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Polyvinyl Alcohol-Stabilized Liquid Metal Hydrogel for Wearable Transient Epidermal Sensors
Abstract
Wearable epidermal sensors are attracting growing interests in human activity monitoring and flexible touch display, but they are still limited by the poor self-healing property and the difficult dissolvable feature. Herein, we report polyvinyl alcohol (PVA)-stabilized liquid metal particles (LMPs) (PVA-LMPs) hydrogels with excellent self-healing performance and the dissolvable feature for wearable epidermal sensors, constructed by dispersing LMPs of eutectic gallium and indium into the borate-modified PVA polymer networks. Interestingly, the PVA-LMPs hydrogels exhibited excellent electrically and mechanically self-healing ability. Moreover, the PVA-LMPs hydrogel can be fabricated as epidermal sensors, which can accurately monitor the human activities. Additionally, the epidermal sensors are dissolvable, showing an attractive feature for on demand transient electronics. It is demonstrated that the hydroxyl groups of PVA can stabilize LMPs via hydrogen-bonding interactions. Furthermore, the dynamic cross-linking bonds between hydrogels and LMPs can rupture and coalesce reversibly in the hydrogel network, which endow the hydrogels with both electrically and mechanically self-healing ability. This work shows the potential of constructing next-generation multifunctional hydrogel-based epidermal sensors for human activity monitoring, wearable healthcare diagnosis, portable electronics, and robot tactile systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cai, G., Wang, J., Qian, K., Chen, J., Li, S., & Lee, P. S. (2017) · Advanced Science · doi:10.1002/advs.201600190 · Cited by 921
Cited by
Hydrogels and Their Role in Biosensing Applications
Herrmann, A., Haag, R., & Schedler, U. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100062 · Cited by 332
Liang, X., Zhong, H.-J., Ding, H., Yu, B., Ma, X., Liu, X., Chong, C.-M., & He, J. (2024) · Polymers · doi:10.3390/polym16192755 · Cited by 332
Biodegradable Materials for Sustainable Health Monitoring Devices
Hosseini, E. S., Dervin, S., Ganguly, P., & Dahiya, R. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c01139 · Cited by 326
A self-healing electrically conductive organogel composite
Zhao, Y., Ohm, Y., Liao, J., Luo, Y., Cheng, H.-Y., Won, P., Roberts, P., Carneiro, M. R., Islam, M. F., Ahn, J. H., et al. (2023) · Nature Electronics · doi:10.1038/s41928-023-00932-0 · Cited by 292
Liquid Metal‐Based Soft Electronics for Wearable Healthcare
Park, Y., Lee, G., Jang, J., Yun, S. M., Kim, E., & Park, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002280 · Cited by 258
Metadata
- Authors
- Liao, M., Liao, H., Ye, J., Wan, P., & Zhang, L.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-11-22
- Volume
- 11
- Issue
- 50
- Pages
- 47358-47364
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2989762356
- Cited by
- 252
- References
- 1
- FWCI
- 7.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polyvinyl Alcohol-Stabilized Liquid Metal Hydrogel for Wearable Transient Epidermal Sensors. https://app.cochat.ai/papers/10.1021/acsami.9b16675
- The paper
- Liao, M., Liao, H., Ye, J., Wan, P., & Zhang, L. (2019). Polyvinyl Alcohol-Stabilized Liquid Metal Hydrogel for Wearable Transient Epidermal Sensors. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.9b16675
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.