The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Coadministration of an Adhesive Conductive Hydrogel Patch and an Injectable Hydrogel to Treat Myocardial Infarction
Abstract
Over the past decade, tissue-engineering strategies, mainly involving injectable hydrogels and epicardial biomaterial patches, have been pursued to treat myocardial infarction. However, only limited therapeutic efficacy is achieved with a single means. Here, a combined therapy approach is proposed, that is, the coadministration of a conductive hydrogel patch and injectable hydrogel to the infarcted myocardium. The self-adhesive conductive hydrogel patch is fabricated based on Fe 3+ -induced ionic coordination between dopamine–gelatin (GelDA) conjugates and dopamine-functionalized polypyrrole (DA–PPy), which form a homogeneous network. The injectable and cleavable hydrogel is formed in situ via a Schiff base reaction between oxidized sodium hyaluronic acid (HA-CHO) and hydrazided hyaluronic acid (HHA). Compared with a single-mode system, injecting the HA-CHO/HHA hydrogel intramyocardially followed by painting a conductive GelDA/DA–PPy hydrogel patch on the heart surface results in a more pronounced improvement of the cardiac function in terms of echocardiographical, histological, and angiogenic outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shin, J., Lee, J. S., Lee, C., Park, H., Yang, K., Jin, Y., Ryu, J. H., Hong, K. S., Moon, S., Chung, H., et al. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201500006 · Cited by 432
Cited by
Supramolecular Adhesive Hydrogels for Tissue Engineering Applications
Zhao, Y., Song, S., Ren, X., Zhang, J., Lin, Q., & Zhao, Y. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00815 · Cited by 711
Recent advances in wet adhesives: Adhesion mechanism, design principle and applications
Cui, C., & Liu, W. (2021) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2021.101388 · Cited by 557
Self-citationPolyphenol scaffolds in tissue engineering
Zhang, X., Li, Z., Yang, P., Duan, G., Liu, X., Gu, Z., & Li, Y. (2021) · Materials Horizons · doi:10.1039/d0mh01317j · Cited by 417
Natural Biopolymer-Based Biocompatible Conductors for Stretchable Bioelectronics
Wang, C., Yokota, T., & Someya, T. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00897 · Cited by 412
Ansari, M. J., Rajendran, R. R., Mohanto, S., Agarwal, U., Panda, K., Dhotre, K., Manne, R., Deepak, A., Zafar, A., Yasir, M., et al. (2022) · Gels · doi:10.3390/gels8070454 · Cited by 337
Constructions and Properties of Physically Cross-Linked Hydrogels Based on Natural Polymers
Yang, J., Chen, Y., Zhao, L., Zhang, J., & Luo, H. (2023) · Polymer Reviews · doi:10.1080/15583724.2022.2137525 · Cited by 261
Teng, L., Shao, Z., Bai, Q., Zhang, X., He, Y., Lu, J., Zou, D., Feng, C., & Dong, C. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202105628 · Cited by 254
Metadata
- Authors
- Wu, T., Cui, C., Huang, Y., Liu, Y., Fan, C., Han, X., Yang, Y., Xu, Z., Liu, B., Fan, G., & Liu, W.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-12-20
- Volume
- 12
- Issue
- 2
- Pages
- 2039-2048
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2995001904
- Cited by
- 213
- References
- 1
- FWCI
- 6.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.