The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Self-Healing and Highly Stretchable Gelatin Hydrogel for Self-Powered Strain Sensor
Abstract
Hydrogels that electronically respond to mechanical changes can be used as strain sensors. However, these systems usually require external power to convert changes in strain into electrical signals. Here, a self-powered strain sensor is developed based on a gelatin-based hydrogel and a galvanic cell. In the hydrogel matrix, hydrophobic interactions and hydrogen bonding between tannic acid and gelatin give the prepared hydrogel great potential for elongation (1600%). The hydrogel also has a rapid self-healing ability (within 0.65 s) and high self-healing efficiency (95%). The hydrogel operates as an efficient electrolyte material and forms a hydrogel battery when assembled with a thin layer of zinc and an air electrode. This device had excellent tolerance to large compressional strain without sacrificing open-circuit voltage. On the basis of this hydrogel battery, we fabricated a self-powered strain sensor by connecting the hydrogel battery to a fixed resistor to form a closed loop. By converting its chemical energy into electrical energy, the self-powered sensor efficiently converted resistance changes, caused by stretching or compression of the hydrogel, into changes in the voltage output signals without external power. Owing to the stretchability of the hydrogel, the self-powered sensor exhibited good response and flexibility. Self-healing and continuous cycling tests confirmed the long-term stability of the device. These properties suggest that our self-powered sensor has a potential for applications to portable and wearable electronic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hierarchical nanostructured conducting polymer hydrogel with high electrochemical activity
Pan, L., Yu, G., Zhai, D., Lee, H. R., Zhao, W., Liu, N., Wang, H., Tee, B. C.-K., Shi, Y., Cui, Y., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1202636109 · Cited by 1,216
Poly(vinyl alcohol) Hydrogel Can Autonomously Self-Heal
Zhang, H., Xia, H., & Zhao, Y. (2012) · ACS Macro Letters · doi:10.1021/mz300451r · Cited by 509
Cited by
Yao, X., Zhang, S., Qian, L., Wei, N., Nica, V., Coseri, S., & Han, F. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202204565 · Cited by 487
Natural Biopolymer-Based Biocompatible Conductors for Stretchable Bioelectronics
Wang, C., Yokota, T., & Someya, T. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00897 · Cited by 412
Cui, C., Fu, Q., Meng, L., Hao, S., Dai, R., & Yang, J. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c00807 · Cited by 353
Tannic acid: a versatile polyphenol for design of biomedical hydrogels
Jafari, H., Ghaffari-Bohlouli, P., Niknezhad, S. V., Abedi, A., Izadifar, Z., Mohammadinejad, R., Varma, R. S., & Shavandi, A. (2022) · Journal of Materials Chemistry B · doi:10.1039/d2tb01056a · Cited by 329
Multifunctional conductive hydrogels and their applications as smart wearable devices
Chen, Z., Chen, Y., Hedenqvist, M. S., Chen, C., Cai, C., Li, H., Liu, H., & Fu, J. (2021) · Journal of Materials Chemistry B · doi:10.1039/d0tb02929g · Cited by 323
Metadata
- Authors
- Wang, J., Tang, F., Wang, Y., Lu, Q., Liu, S., & Li, L.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-12-06
- Volume
- 12
- Issue
- 1
- Pages
- 1558-1566
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2991884820
- Cited by
- 251
- References
- 2
- FWCI
- 10.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.