The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Flexible and Transparent Cellulose-Based Ionic Film as a Humidity Sensor
Abstract
A transparent and flexible cellulose/KOH composite ionic film (CKF) is fabricated as a humidity sensor. CKF exhibits high optical transmittance (87.14% at 550 nm), which has rarely been reported among humidity sensors as a result of the small pore size of the cellulose matrix caused by water-evaporation-induced dense packing and uniform distribution of amorphous KOH via simply soaking-drying. CKF also possesses flexibility and robust mechanical property. The conductive CKF shows fast and reversible real-time response to relative humidity (RH) in the 11.3-97.3% RH range with conductance varying over 200 times, response/recovery times of 6.0/10.8 s, which are shorter than the majority of the reported values, as well as a hysteresis error of 0.57%, which is significantly less than that reported in the literature. Furthermore, CKF is insensitive to both the temperature (10-70 °C) and pressure (0-120 kPa), indicating high selectivity as humidity sensors. In both the non-contact fingertip moisture detection and breathing rate detection, the flexible and transparent CKF-based humidity sensor responds favorably to RH change. Moreover, a flexible and transparent CKF-based wearable skin moisture detector is assembled to measure the moisture of human skin in different situations, whose measurement is very close to the commercial detector. The results offer real-time moisture information on human skin and demonstrate the potential of a CKF-based moisture detector as a promising modular component in integrated intelligent wearable equipment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trung, T. Q., Ramasundaram, S., Hwang, B., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504441 · Cited by 870
Porous Ionic Membrane Based Flexible Humidity Sensor and its Multifunctional Applications
Li, T., Li, L., Sun, H., Xu, Y., Wang, X., Luo, H., Liu, Z., & Zhang, T. (2017) · Advanced Science · doi:10.1002/advs.201600404 · Cited by 298
Cited by
Evolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Recent advances in humidity sensors for human body related humidity detection
Duan, Z., Jiang, Y., & Tai, H. (2021) · Journal of Materials Chemistry C · doi:10.1039/d1tc04180k · Cited by 365
Zarei, M., Lee, G., Lee, S. G., & Cho, K. (2023) · Advanced Materials · doi:10.1002/adma.202203193 · Cited by 345
Multifunctional Flexible Humidity Sensor Systems Towards Noncontact Wearable Electronics
Lu, Y., Yang, G., Shen, Y., Yang, H., & Xu, K. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00895-5 · Cited by 320
Guo, Y., Wei, X., Gao, S., Yue, W., Li, Y., & Shen, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202104288 · Cited by 279
Metadata
- Authors
- Wang, Y., Zhang, L., Zhou, J., & Lu, A.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-01-21
- Volume
- 12
- Issue
- 6
- Pages
- 7631-7638
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W3001408443
- Cited by
- 185
- References
- 2
- FWCI
- 8.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.