Cited by 8Wound Healing and TreatmentsElectrospun Nanofibers in Biomedical ApplicationsMetal-Organic Frameworks: Synthesis and Applications

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Cu-BTC MOFs Grown In Situ on Poly(ionic liquid)-Based Electrospun Fibrous Membranes for Wound Dressings

Abstract

Developing wound dressings with antibacterial, good moisture absorption, air permeability and inflammatory inhibition activities to promote wound healing effectively is highly desirable in clinical practice. Herein, a multifunctional wound dressing with air permeability, hygroscopicity and antibacterial activity was developed by in situ growth of a metal–organic framework (Cu-BTC) benzene-1,3,5-tricarboxylate (BTC) on poly(ionic liquid) (PIL)-based fibrous membranes. The Cu-BTC was grown in situ on an imidazolium-based PIL fibrous membrane via coordination bonds, which increased the stability and dispersion of the Cu-BTC. The porous structure of electrospinning and Cu-BTC allows the breathable dressings to absorb wound exudate and regulate the wound microenvironment. The imidazolium-based IL and Cu 2+ released from Cu-BTC endow the dressing with effective bactericidal activities both in vitro and in vivo, especially for Cu-BTC 60 /PIL, in which more than 96% of bacteria are inactivated. Moreover, an in vivo bacterial infection wound study revealed that the dressing with good biocompatibility can effectively sterilize Staphylococcus aureus while suppressing inflammation and promoting wound healing. The developed wound dressing synergistically combines the antibacterial therapeutic effect of PIL and the release of Cu 2+ from Cu-BTC for effective wound healing, which may provide an ideal clinical intervention strategy for infected wounds.

Overview

Integrity signals

Registry

Crossref · 10.1021/acsapm.4c02401

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 41 references

Cited by

Sorted by citations

See all 8

Metadata

Authors
Zhou, Y., Gao, S., Zhou, J., He, Q., Yuan, X., Guo, J., & Yan, F.
Affiliations
  • Soochow University (CN)
  • Donghua University (CN)
Corresponding author
  • Guo, Jiangna
  • Yan, Feng
Venue
ACS Applied Polymer Materials
Published
2024-11-28
Volume
6
Issue
23
Pages
14410-14420
ISSN
2637-6105 (ISSN-L)
OpenAlex
W4404829403
Cited by
8
References
41
Citations by year
2026: 4 · 2025: 4
FWCI
1.27
Type
journal article
Language
en
Open access
closed
Locations
ACS Applied Polymer Materials (publishedVersion)
Funders
  • Suzhou Municipal Science and Technology Bureau (SKJY2021042)
  • Natural Science Research of Jiangsu Higher Education Institutions of China (23KJA150008)
  • Collaborative Innovation Center of Suzhou Nano Science and Technology
  • Jiangsu Provincial Department of Science and Technology (BK20220007)
  • National Natural Science Foundation of China (52333002)
  • Science and Technology Program of Suzhou (SNG2021011)
  • Priority Academic Program Development of Jiangsu Higher Education Institutions
Topics
  • Health Sciences › Medicine › Surgery › Wound Healing and Treatments
  • Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
  • Physical Sciences › Chemistry › Inorganic Chemistry › Metal-Organic Frameworks: Synthesis and Applications
Keywords
HKUST-1, metal-organic frameworks, wound dressings, poly(ionic liquids), electrospun fibrous membranes, imidazolium ionic liquids, in situ growth, antibacterial activity, copper ion release, Staphylococcus aureus, wound infection, wound healing, air permeability, hygroscopicity, anti-inflammatory activity, wound exudate absorption

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cu-BTC MOFs Grown In Situ on Poly(ionic liquid)-Based Electrospun Fibrous Membranes for Wound Dressings. https://app.cochat.ai/papers/10.1021/acsapm.4c02401
The paper
Zhou, Y., Gao, S., Zhou, J., He, Q., Yuan, X., Guo, J., & Yan, F. (2024). Cu-BTC MOFs Grown In Situ on Poly(ionic liquid)-Based Electrospun Fibrous Membranes for Wound Dressings. ACS Applied Polymer Materials. https://doi.org/10.1021/acsapm.4c02401