CoChat

Perfluorohexane-Loaded Polymeric Nanovesicles with Oxygen Supply for Enhanced Sonodynamic Therapy

Zeng, Qiang, Qiao, Lijuan, Cheng, Lili, Li, Chao, Cao, Zhong, Chen, Zhiyi, Wang, Yi, Liu, Jie · 2020 · ACS Biomaterials Science & Engineering
Cited by 59

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Sonodynamic therapy (SDT), as a new method of non-invasive tumor treatment developed from photodynamic therapy (PDT), can overcome the disadvantage of poor laser penetration while retaining the function of PDT. However, the lack of efficient sonosensitizer accumulation and the hypoxic environment in tumor sites limited the therapeutic efficacy of SDT. Here, we constructed a highly efficient liquid fluorocarbon-encapsulated polymeric nanovesicle for enhanced sonodynamic efficacy as well as tumor hypoxia relief. This multifunctional nanovesicle was constructed by fluorinated cationic polymer C 9 F 17 -PAsp(DET) with PEG-conjugated protoporphyrin IX (PEG-PpIX) modification, which could yield the simultaneous loading of perfluorohexane (PFH) and oxygen. We found that the PAsp(DET)-PpIX-PEG@PFH nanovesicles could not only generate the reactive oxygen species (ROS) under ultrasound irradiation after intravenous ( i . v .) injection but also could generate and prolong the ROS under nanovesicle preparation by ultrasonication in vitro, so-called the ″exogenous ROS”, which might result in enhanced cytotoxicity in tumor tissue. Furthermore, oxygen-loaded PAsp(DET)-PpIX-PEG nanovesicles could not only reduce therapeutic resistance by relieving tumor hypoxia but also increase ROS production for enhanced sonodynamic therapy. An in vivo study revealed that the nanovesicles could accumulate in the tumor site after i.v. injection and achieved remarkable tumor growth inhibition in both with and without preloaded oxygen groups, which indicated that the nanovesicle system could efficiently achieve oxygen loading during in vivo circulation and provide a better solution for SDT application.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsbiomaterials.0c00407

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 59

Metadata

Authors
Zeng, Q., Qiao, L., Cheng, L., Li, C., Cao, Z., Chen, Z., Wang, Y., & Liu, J.
Venue
ACS Biomaterials Science & Engineering
Published
2020-03-30
Volume
6
Issue
5
Pages
2956-2969
ISSN
2373-9878 (ISSN-L)
OpenAlex
W3013584406
Cited by
59
References
2
FWCI
2.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Perfluorohexane-Loaded Polymeric Nanovesicles with Oxygen Supply for Enhanced Sonodynamic Therapy. https://app.cochat.ai/papers/10.1021/acsbiomaterials.0c00407
The paper
Zeng, Q., Qiao, L., Cheng, L., Li, C., Cao, Z., Chen, Z., Wang, Y., & Liu, J. (2020). Perfluorohexane-Loaded Polymeric Nanovesicles with Oxygen Supply for Enhanced Sonodynamic Therapy. ACS Biomaterials Science & Engineering. https://doi.org/10.1021/acsbiomaterials.0c00407

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.