Pulse Electrochemical Driven Rapid Layer-by-Layer Assembly of Polydopamine and Hydroxyapatite Nanofilms via Alternative Redox in Situ Synthesis for Bone Regeneration
Abstract
Polydopamine (PDA) is an important candidate material for the surface modification of biomedical devices because of its good adhesiveness and biocompatibility. However, PDA nanofilms lack osteoinductivity, limiting their applications in bone tissue engineering. Hydroxyapatite nanoparticles (HA-NPs) are the major component of natural bone, which can be used to effectively enhance the osteoinductivity of PDA nanofilms. Herein, we developed a pulse electrochemical driven layer-by-layer (PED-LbL) assembly process to rapidly deposit HA-NPs and PDA (HA-PDA) multilayer nanofilms. In this process, PDA and HA-NPs are in situ synthesized in two sequential oxidative and reductive pulses in each electrochemical deposition cycle and alternately deposited on the substrate surfaces. PDA assists the in situ synthesis of HA-NPs by working as a template, which avoids the noncontrollable HA nucleation and aggregation. The HA-PDA multilayer nanofilms serve as a tunable reservoir to deliver bone morphogenetic protein-2 and exhibit high osteoinductivity both in vitro and in vivo . This PED-LbL assembly process breaks the limitation of traditional LbL assembly, allowing not only the rapid assembly of oppositely charged polyelectrolytes but also the in situ synthesis of organic/inorganic NPs that are uniformly incorporated in the nanofilm. It has broad applications in the preparation of versatile surface coatings on various biomedical devices.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In PED, the formation of PDA and HA can occur alternatively in a single chemical bath by alternating the applied voltage.
“In PED, the formation of PDA and HA can occur alternatively in a single chemical bath by alternating the applied voltage.”
From Strategies for Using Polydopamine to Induce Biomineralization of Hydroxyapatite on Implant Materials for Bone Tissue Engineering (2020) · cites this paper as [31]
PDA-HA has high osteoconductivity and biocompatibility when applied, as shown by both in vitro and in vivo studies.
“Both in vitro and in vivo studies showed that PDA-HA has high osteoconductivity and biocompatibility when applied.”
From Strategies for Using Polydopamine to Induce Biomineralization of Hydroxyapatite on Implant Materials for Bone Tissue Engineering (2020) · cites this paper as [31]
The formation of PDA and HA can be achieved by employing an electrochemical approach.
“Interestingly, the formation of PDA and HA can also be achieved by employing an electrochemical approach [30,31].”
From Strategies for Using Polydopamine to Induce Biomineralization of Hydroxyapatite on Implant Materials for Bone Tissue Engineering (2020) · cites this paper as [31]
Cites
Mussel‐Inspired Polydopamine Coating as a Universal Route to Hydroxyapatite Crystallization
Ryu, J., Ku, S. H., Lee, H., & Park, C. B. (2010) · Advanced Functional Materials · doi:10.1002/adfm.200902347 · Cited by 778 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Kaushik, N., Nhat Nguyen, L., Kim, J. H., Choi, E. H., & Kumar Kaushik, N. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21186544 · Cited by 76 · see citing works
“Interestingly, the formation of PDA and HA can also be achieved by employing an electrochemical approach [30,31].”
BackgroundMethodPolydopamine-Modified functional materials promote bone regeneration
Wang, J., Cui, Y., Zhang, B., Sun, S., Xu, H., Yao, M., Wu, D., & Wang, Y. (2024) · Materials & Design · doi:10.1016/j.matdes.2024.112655 · Cited by 56 · see citing works
- Authors
- Xie, C., Lu, X., Wang, K., Yuan, H., Fang, L., Zheng, X., Chan, C., Ren, F., & Zhao, C.
- Affiliations
- Southwest Jiaotong University (CN)
- Sichuan University (CN)
- South China University of Technology (CN)
- Chinese University of Hong Kong (HK)
- Southern University of Science and Technology (CN)
- Corresponding author
- Lu, Xiong
- ORCID
- Venue
- ACS Biomaterials Science & Engineering
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-05-12
- Volume
- 2
- Issue
- 6
- Pages
- 920-928
- ISSN
- 2373-9878 (ISSN-L)
- OpenAlex
- W2460529457
- Cited by
- 62
- References
- 1
- Citations by year
- 2025: 4 · 2024: 6 · 2023: 11 · 2022: 7 · 2021: 3 · 2020: 5 · 2019: 10 · 2018: 3 · 2017: 11 · 2016: 2
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- ACS Biomaterials Science & Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Ministry of Science and Technology of the People's Republic of China (2015AA034202)
- Openfund of Key Lab of Advanced Technologies of Materials
- The 2015 Doctoral Innovation Funds of Southwest Jiaotong University
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Physical Sciences › Engineering › Mechanical Engineering › Surface Treatment and Coatings
- Keywords
- polydopamine, hydroxyapatite nanoparticles, layer-by-layer assembly, in situ synthesis, multilayer nanofilms, bone regeneration, osteoinduction, polyelectrolyte multilayers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review