Cited by 62Bone Tissue Engineering MaterialsPolymer Surface Interaction StudiesSurface Treatment and Coatings

Pulse Electrochemical Driven Rapid Layer-by-Layer Assembly of Polydopamine and Hydroxyapatite Nanofilms via Alternative Redox in Situ Synthesis for Bone Regeneration

Xie, Chaoming, Lu, Xiong, Wang, Kefeng, Yuan, Huipin, Fang, Liming, Zheng, Xiaotong, Chan, Chunwai, Ren, Fuzeng +1 more·2016·ACS Biomaterials Science & Engineering

Abstract

Polydopamine (PDA) is an important candidate material for the surface modification of biomedical devices because of its good adhesiveness and biocompatibility. However, PDA nanofilms lack osteoinductivity, limiting their applications in bone tissue engineering. Hydroxyapatite nanoparticles (HA-NPs) are the major component of natural bone, which can be used to effectively enhance the osteoinductivity of PDA nanofilms. Herein, we developed a pulse electrochemical driven layer-by-layer (PED-LbL) assembly process to rapidly deposit HA-NPs and PDA (HA-PDA) multilayer nanofilms. In this process, PDA and HA-NPs are in situ synthesized in two sequential oxidative and reductive pulses in each electrochemical deposition cycle and alternately deposited on the substrate surfaces. PDA assists the in situ synthesis of HA-NPs by working as a template, which avoids the noncontrollable HA nucleation and aggregation. The HA-PDA multilayer nanofilms serve as a tunable reservoir to deliver bone morphogenetic protein-2 and exhibit high osteoinductivity both in vitro and in vivo . This PED-LbL assembly process breaks the limitation of traditional LbL assembly, allowing not only the rapid assembly of oppositely charged polyelectrolytes but also the in situ synthesis of organic/inorganic NPs that are uniformly incorporated in the nanofilm. It has broad applications in the preparation of versatile surface coatings on various biomedical devices.

Integrity signals

Registry

Crossref · 10.1021/acsbiomaterials.6b00015

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Xie, C., Lu, X., Wang, K., Yuan, H., Fang, L., Zheng, X., Chan, C., Ren, F., & Zhao, C.
Affiliations
  • Southwest Jiaotong University (CN)
  • Sichuan University (CN)
  • South China University of Technology (CN)
  • Chinese University of Hong Kong (HK)
  • Southern University of Science and Technology (CN)
Corresponding author
Lu, Xiong
Venue
ACS Biomaterials Science & Engineering
Published
2016-05-12
Volume
2
Issue
6
Pages
920-928
ISSN
2373-9878 (ISSN-L)
OpenAlex
W2460529457
Cited by
62
References
1
Citations by year
2025: 4 · 2024: 6 · 2023: 11 · 2022: 7 · 2021: 3 · 2020: 5 · 2019: 10 · 2018: 3 · 2017: 11 · 2016: 2
FWCI
4.18
Type
journal article
Language
en
Open access
closed
Locations
  • ACS Biomaterials Science & Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Ministry of Science and Technology of the People's Republic of China (2015AA034202)
  • Openfund of Key Lab of Advanced Technologies of Materials
  • The 2015 Doctoral Innovation Funds of Southwest Jiaotong University
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
  • Physical Sciences › Engineering › Mechanical Engineering › Surface Treatment and Coatings
Keywords
polydopamine, hydroxyapatite nanoparticles, layer-by-layer assembly, in situ synthesis, multilayer nanofilms, bone regeneration, osteoinduction, polyelectrolyte multilayers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review