The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Magnesium Phosphate Cement Systems for Hard Tissue Applications: A Review
Abstract
In the search for more ideal bone graft materials for clinical application, the investigation into ceramic bone cements or bone void filler is ongoing. Calcium phosphate-based materials have been widely explored and implemented for medical use in bone defect repair. Such materials are an excellent choice because the implant mimics the natural chemistry of mineralized bone matrix and in injectable cement form, can be implemented with relative ease. However, of the available calcium phosphate cements, none fully meet the ideal standard, displaying low strengths and acidic setting reactions or slow setting times, and are often very slow to resorb in vivo. The study of magnesium phosphates for bone cements is a relatively new field compared to traditional calcium phosphate bone cements. Although reports are more limited, preliminary studies have shown that magnesium phosphate cements (MPC) may be a strong alternative to calcium phosphates for certain applications. The goal of the present publication is to review the history and achievements of magnesium phosphate-based cements or bone void fillers to date, assess how these cements compare with calcium phosphate competitors and to analyze the future directions and outlook for the research, development, and clinical implementation of these cements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Giannoudis, P. V., Dinopoulos, H., & Tsiridis, E. (2005) · Injury · doi:10.1016/j.injury.2005.07.029 · Cited by 2,078
Calcium phosphate cements for bone substitution: Chemistry, handling and mechanical properties
Zhang, J., Liu, W., Schnitzler, V., Tancret, F., & Bouler, J.-M. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.11.001 · Cited by 667
Injectable biodegradable materials for orthopedic tissue engineering
Temenoff, J. S., & Mikos, A. G. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00108-3 · Cited by 554
Cited by
Research progresses on magnesium phosphate cement: A review
Haque, M. A., & Chen, B. (2019) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2019.03.304 · Cited by 348
He, L., Wu, F., Ma, Y., Li, Z., Chen, A., Zhao, B., & Cao, J. (2025) · Engineering Structures · doi:10.1016/j.engstruct.2025.121018 · Cited by 2
Metadata
- Authors
- Ostrowski, N., Roy, A., & Kumta, P. N.
- Venue
- ACS Biomaterials Science & Engineering
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-06-06
- Volume
- 2
- Issue
- 7
- Pages
- 1067-1083
- ISSN
- 2373-9878 (ISSN-L)
- OpenAlex
- W2364756455
- Cited by
- 216
- References
- 3
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnesium Phosphate Cement Systems for Hard Tissue Applications: A Review. https://app.cochat.ai/papers/10.1021/acsbiomaterials.6b00056
- The paper
- Ostrowski, N., Roy, A., & Kumta, P. N. (2016). Magnesium Phosphate Cement Systems for Hard Tissue Applications: A Review. ACS Biomaterials Science & Engineering. https://doi.org/10.1021/acsbiomaterials.6b00056
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.