CoChat

Accurate Evaluation of Active-Site Density (SD) and Turnover Frequency (TOF) of PGM-Free Metal–Nitrogen-Doped Carbon (MNC) Electrocatalysts using CO Cryo Adsorption

Luo, Fang, Choi, Chang Hyuck, Primbs, Mathias J.M., Ju, Wen, Li, Shuang, Leonard, Nathaniel D., Thomas, Arne, Jaouen, Frédéric, Strasser, Peter · 2019 · ACS Catalysis
Cited by 120

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The number of catalytically active sites (site density, SD) and the catalytic turnover frequency (TOF) are critical for meaningful comparisons between catalytic materials and their rational improvement. SD and TOF numbers have remained elusive for PGM-free, metal/nitrogen-doped porous carbon electrocatalysts (MNC), in particular, FeNC materials that are now intensively investigated and widely utilized to catalyze the oxygen reduction reaction (ORR) in fuel cell cathodes. Here, we apply CO cryo sorption and desorption to evaluate SD and TOF numbers of a state-of-art FeNC ORR electrocatalyst with atomically dispersed coordinative FeN x ( x ≤ 4) sites in acid and alkaline conditions. More specifically, we study the impact of thermal pretreatment conditions prior to assessing the number of sorption-active FeN x sites. We show that the pretreatment temperature sensitively affects the CO sorption uptake through a progressive thermal removal of airborne adsorbates, which, in turn, controls the resulting catalytic SD numbers. We correlate CO uptake with CO desorption and analyze the observed temperature-programmed desorption characteristics. The CO uptakes increased from 45 nmol·mg –1 catalyst at 300 °C cleaning to 65 nmol·mg –1 catalyst at 600 °C cleaning, where it leveled off. These values were converted into apparent SD values of 2.7 × 10 19 to 3.8 × 10 19 surface sites per gram catalyst. Because of similar ORR activity of the pristine catalyst and of the sample after 600 °C cleaning step, we conclude that the nature and number of surface FeN x sites remained largely unaffected up to 600 °C and that cleaning to less than 600 °C was insufficient to free the sites from previously adsorbed species, completely or partially impeding CO adsorption. Cleaning beyond that temperature, however, led to undesired chemical modifications of the FeN x moieties, resulting in higher TOF. In all, this study identifies and recommends a practical and useful protocol for the accurate evaluation of catalytic SD and TOF parameters of PGM-free ORR electrocatalyst, which enables a more rational future catalyst development and improvement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acscatal.9b00588

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Luo, F., Choi, C. H., Primbs, M. J. M., Ju, W., Li, S., Leonard, N. D., Thomas, A., Jaouen, F., & Strasser, P.
Venue
ACS Catalysis
Published
2019-04-15
Volume
9
Issue
6
Pages
4841-4852
ISSN
2155-5435 (ISSN-L)
OpenAlex
W2938817790
Cited by
120
References
2
FWCI
3.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.