Compaction of Duplex Nucleic Acids upon Native Electrospray Mass Spectrometry
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Native mass spectrometry coupled to ion mobility spectrometry is a promising tool for structural biology. Intact complexes can be transferred to the mass spectrometer and, if native conformations survive, collision cross sections give precious information on the structure of each species in solution. Based on several successful reports for proteins and their complexes, the conformation survival becomes more and more taken for granted. Here we report on the fate of nucleic acids conformation in the gas phase. Disturbingly, we found that DNA and RNA duplexes, at the electrospray charge states naturally obtained from native solution conditions (≥ 100 mM aqueous NH 4 OAc), are significantly more compact in the gas phase compared to the canonical solution structures. The compaction is observed for short (12-bp) and long (36-bp) duplexes, and for DNA and RNA alike. Molecular modeling (density functional calculations on small helices, semi-empirical calculations on up to 12-bp, and molecular dynamics on up to 36-bp duplexes) demonstrates that the compaction is due to phosphate group self-solvation prevailing over Coulomb-driven expansion. Molecular dynamics simulations starting from solution structures do not reproduce the experimental compaction. To be experimentally relevant, molecular dynamics sampling should reflect the progressive structural rearrangements occurring during desolvation. For nucleic acid duplexes, the compaction observed for low charge states results from novel phosphate-phosphate hydrogen bonds formed across both grooves at the very late stages of electrospray.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Native Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602
Cited by
Fundamentals of ion mobility spectrometry
Gabelica, V., & Marklund, E. (2018) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2017.10.022 · Cited by 440
Self-citationKonermann, L. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1739-3 · Cited by 243
Adding a new separation dimension to MS and LC–MS: What is the utility of ion mobility spectrometry?
D'Atri, V., Causon, T., Hernandez‐Alba, O., Mutabazi, A., Veuthey, J., Cianferani, S., & Guillarme, D. (2018) · Journal of Separation Science · doi:10.1002/jssc.201700919 · Cited by 184
Ion mobility in the pharmaceutical industry: an established biophysical technique or still niche?
Campuzano, I. D., & Lippens, J. L. (2018) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2017.11.008 · Cited by 42
Allison, T. M., Barran, P., Cianférani, S., Degiacomi, M. T., Gabelica, V., Grandori, R., Marklund, E. G., Menneteau, T., Migas, L. G., Politis, A., et al. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05791 · Cited by 38
Self-citation
Metadata
- Authors
- Porrini, M., Rosu, F., Rabin, C., Darré, L., Gómez, H., Orozco, M., & Gabelica, V.
- Venue
- ACS Central Science
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-04-26
- Volume
- 3
- Issue
- 5
- Pages
- 454-461
- ISSN
- 2374-7943 (ISSN-L)
- 2374-7951
- OpenAlex
- W2953195358
- Cited by
- 105
- References
- 1
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Compaction of Duplex Nucleic Acids upon Native Electrospray Mass Spectrometry. https://app.cochat.ai/papers/10.1021/acscentsci.7b00084
- The paper
- Porrini, M., Rosu, F., Rabin, C., Darré, L., Gómez, H., Orozco, M., & Gabelica, V. (2017). Compaction of Duplex Nucleic Acids upon Native Electrospray Mass Spectrometry. ACS Central Science. https://doi.org/10.1021/acscentsci.7b00084
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.