Nanoscale Ion Emitters in Native Mass Spectrometry for Measuring Ligand–Protein Binding Affinities
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
High Resolution Image Download MS PowerPoint Slide Electrospray ionization (ESI) mass spectrometry (MS) is a crucial method for rapidly determining the interactions between small molecules and proteins with ultrahigh sensitivity. However, nonvolatile molecules and salts that are often necessary to stabilize the native structures of protein–ligand complexes can readily adduct to protein ions, broaden spectral peaks, and lower signal-to-noise ratios in native MS. ESI emitters with narrow tip diameters (∼250 nm) were used to significantly reduce the extent of adduction of salt and nonvolatile molecules to protein complexes to more accurately measure ligand–protein binding constants than by use of conventional larger-bore emitters under these conditions. As a result of decreased salt adduction, peaks corresponding to protein–ligand complexes that differ in relative molecular weight by as low as 0.06% can be readily resolved. For low-molecular-weight anion ligands formed from sodium salts, anion-bound and unbound protein ions that differ in relative mass by 0.2% were completely baseline resolved using nanoscale emitters, which was not possible under these conditions using conventional emitters. Owing to the improved spectral resolution obtained using narrow-bore emitters and an analytically derived equation, K d values were simultaneously obtained for at least six ligands to a single druggable protein target from one spectrum for the first time. This research suggests that ligand–protein binding constants can be directly and accurately measured from solutions with high concentrations of nonvolatile buffers and salts by native MS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Susa, A. C., Xia, Z., & Williams, E. R. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04897 · Cited by 167
Gavriilidou, A. F. M., Gülbakan, B., & Zenobi, R. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02478 · Cited by 53
Cited by
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
VanAernum, Z. L., Busch, F., Jones, B. J., Jia, M., Chen, Z., Boyken, S. E., Sahasrabuddhe, A., Baker, D., & Wysocki, V. H. (2020) · Nature Protocols · doi:10.1038/s41596-019-0281-0 · Cited by 169
Nguyen, G. T. H., Bennett, J. L., Liu, S., Hancock, S. E., Winter, D. L., Glover, D. J., & Donald, W. A. (2021) · Journal of the American Chemical Society · doi:10.1021/jacs.1c10408 · Cited by 66
Self-citation
Metadata
- Authors
- Nguyen, G. T. H., Tran, T. N., Podgorski, M. N., Bell, S. G., Supuran, C. T., & Donald, W. A.
- Venue
- ACS Central Science
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-01-14
- Volume
- 5
- Issue
- 2
- Pages
- 308-318
- ISSN
- 2374-7943 (ISSN-L)
- 2374-7951
- OpenAlex
- W2910553840
- Cited by
- 125
- References
- 2
- FWCI
- 6.51
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanoscale Ion Emitters in Native Mass Spectrometry for Measuring Ligand–Protein Binding Affinities. https://app.cochat.ai/papers/10.1021/acscentsci.8b00787
- The paper
- Nguyen, G. T. H., Tran, T. N., Podgorski, M. N., Bell, S. G., Supuran, C. T., & Donald, W. A. (2019). Nanoscale Ion Emitters in Native Mass Spectrometry for Measuring Ligand–Protein Binding Affinities. ACS Central Science. https://doi.org/10.1021/acscentsci.8b00787
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.