The DOI matches its Crossref record; 159 of the 159 references it cites were found in a registry or an index.
Functional Conductive Hydrogels for Bioelectronics
Open accessAbstract
Conductive hydrogels are widely used in various applications, such as artificial skin, flexible and implantable bioelectronics, and tissue engineering. However, it is still a challenge to formulate hydrogels with high electrical conductivity without compromising their physicochemical properties (e.g., toughness, stretchability, and biocompatibility). Additionally, incorporating other functions, such as self-healing, shape memory, and wet adhesion, into conductive hydrogels is critical to many practical applications of hydrogel bioelectronics. In this Review, we highlight recent progress in the development of functional conductive hydrogels. We, then, discuss the potential applications and challenges faced by conductive hydrogels in the areas of wearable/implantable electronics and cell/tissue engineering. Conductive hydrogel can serve as an important building block for bioelectronic devices in personalized healthcare and other bioengineering areas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Advances in engineering hydrogels
Zhang, Y. S., & Khademhosseini, A. (2017) · Science · doi:10.1126/science.aaf3627 · Cited by 2,908
Yuk, H., Lu, B., & Zhao, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,108
Zhao, X., Wu, H., Guo, B., Dong, R., Qiu, Y., & Ma, P. X. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.01.011 · Cited by 1,971
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Yang, C., & Suo, Z. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0018-7 · Cited by 1,709
Pan, L., Chortos, A., Yu, G., Wang, Y., Isaacson, S., Allen, R., Shi, Y., Dauskardt, R., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms4002 · Cited by 1,519
Dry double-sided tape for adhesion of wet tissues and devices
Yuk, H., Varela, C. E., Nabzdyk, C. S., Mao, X., Padera, R. F., Roche, E. T., & Zhao, X. (2019) · Nature · doi:10.1038/s41586-019-1710-5 · Cited by 1,471
A highly stretchable, transparent, and conductive polymer
Wang, Y., Zhu, C., Pfattner, R., Yan, H., Jin, L., Chen, S., Molina-Lopez, F., Lissel, F., Liu, J., Rabiah, N. I., et al. (2017) · Science Advances · doi:10.1126/sciadv.1602076 · Cited by 1,442
Hydrogels and Hydrogel-Derived Materials for Energy and Water Sustainability
Guo, Y., Bae, J., Fang, Z., Li, P., Zhao, F., & Yu, G. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00345 · Cited by 1,395
Cited by
K, N., & Rout, C. S. (2021) · RSC Advances · doi:10.1039/d0ra07800j · Cited by 1,354
Recent advances in conductive hydrogels: classifications, properties, and applications
Zhu, T., Ni, Y., Biesold, G. M., Cheng, Y., Ge, M., Li, H., Huang, J., Lin, Z., & Lai, Y. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00173j · Cited by 738
Wu, N., Yang, Y., Wang, C., Wu, Q., Pan, F., Zhang, R., Liu, J., & Zeng, Z. (2023) · Advanced Materials · doi:10.1002/adma.202207969 · Cited by 372
Wearable Biosensors: An Alternative and Practical Approach in Healthcare and Disease Monitoring
Sharma, A., Badea, M., Tiwari, S., & Marty, J. L. (2021) · Molecules · doi:10.3390/molecules26030748 · Cited by 357
Multifunctional conductive hydrogels and their applications as smart wearable devices
Chen, Z., Chen, Y., Hedenqvist, M. S., Chen, C., Cai, C., Li, H., Liu, H., & Fu, J. (2021) · Journal of Materials Chemistry B · doi:10.1039/d0tb02929g · Cited by 323
Yuan, Y., Zhang, Q., Lin, S., & Li, J. (2025) · Progress in Materials Science · doi:10.1016/j.pmatsci.2024.101378 · Cited by 307
Su, G., Yin, S., Guo, Y., Zhao, F., Guo, Q., Zhang, X., Zhou, T., & Yu, G. (2021) · Materials Horizons · doi:10.1039/d1mh00085c · Cited by 293
Hydrogels for Flexible Electronics
Zhang, Y., Tan, Y., Lao, J., Gao, H., & Yu, J. (2023) · ACS Nano · doi:10.1021/acsnano.3c02897 · Cited by 291
Self-citationHighly conductive tissue-like hydrogel interface through template-directed assembly
Chong, J., Sung, C., Nam, K. S., Kang, T., Kim, H., Lee, H., Park, H., Park, S., & Kang, J. (2023) · Nature Communications · doi:10.1038/s41467-023-37948-1 · Cited by 286
Conductive polymer based hydrogels and their application in wearable sensors: a review
Liu, D., Huyan, C., Wang, Z., Guo, Z., Zhang, X., Torun, H., Mulvihill, D., Xu, B. B., & Chen, F. (2023) · Materials Horizons · doi:10.1039/d3mh00056g · Cited by 282
Hao, S., Shao, C., Meng, L., Cui, C., Xu, F., & Yang, J. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c18250 · Cited by 258
Yang, Y., Wu, N., Li, B., Liu, W., Pan, F., Zeng, Z., & Liu, J. (2022) · ACS Nano · doi:10.1021/acsnano.2c06164 · Cited by 255
Zhang, Y., Zhang, R., & Tao, Y. (2023) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2023.121300 · Cited by 27
Metadata
- Authors
- Fu, F., Wang, J., Zeng, H., & Yu, J.
- Venue
- ACS Materials Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-08-25
- Volume
- 2
- Issue
- 10
- Pages
- 1287-1301
- ISSN
- 2639-4979 (ISSN-L)
- OpenAlex
- W3080858763
- Cited by
- 364
- References
- 159
- FWCI
- 13.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.