The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Surface Functionalization of Ti3C2Tx MXene with Highly Reliable Superhydrophobic Protection for Volatile Organic Compounds Sensing
Abstract
Two-dimensional (2D) transition-metal carbides (Ti 3 C 2 T x MXene) have received a great deal of attention for potential use in gas sensing showing the highest sensitivity among 2D materials and good gas selectivity. However, one of the long-standing challenges of the MXenes is their poor stability against hydration and oxidation in a humid environment, limiting their long-term storage and applications. Integration of an effective protection layer with MXenes shows promise for overcoming this major drawback. Herein, we demonstrate a surface functionalization strategy for Ti 3 C 2 T x with fluoroalkylsilane (FOTS) molecules through surface treatment, providing not only a superhydrophobic surface, mechanical/environmental stability but also enhanced sensing performance. The experimental results show that high sensitivity, good repeatability, long-term stability, and selectivity and faster response/recovery property were achieved by the FOTS-functionalized when Ti 3 C 2 T x was integrated into chemoresistive sensors sensitive to oxygen-containing volatile organic compounds (ethanol, acetone). FOTS functionalization provided protection to sensing response when the dynamic response of the Ti 3 C 2 T x -F sensor to 30 ppm of ethanol was measured over in the 5 to 80% relative humidity range. Density functional theory simulations suggested that the strong adsorption energy of ethanol on Ti 3 C 2 T x -F and the local structure deformation induced by ethanol adsorption, contributing to the gas-sensing enhancement. This study offers a facile and practical solution for developing highly reliable MXene based gas-sensing devices with response that is stable in air and in the presence of water.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Projector augmented-wave method
Blöchl, P. E. (1994) · Physical Review B · doi:10.1103/physrevb.50.17953 · Cited by 92,732
Metallic Ti3C2T x MXene Gas Sensors with Ultrahigh Signal-to-Noise Ratio
Kim, S. J., Koh, H.-J., Ren, C. E., Kwon, O., Maleski, K., Cho, S.-Y., Anasori, B., Kim, C.-K., Choi, Y.-K., Kim, J., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07460 · Cited by 1,699
Room Temperature Gas Sensing of Two-Dimensional Titanium Carbide (MXene)
Lee, E., VahidMohammadi, A., Prorok, B. C., Yoon, Y. S., Beidaghi, M., & Kim, D.-J. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b11055 · Cited by 878
Ultralow Density, Monolithic WS2, MoS2, and MoS2/Graphene Aerogels
Worsley, M. A., Shin, S. J., Merrill, M. D., Lenhardt, J., Nelson, A. J., Woo, L. Y., Gash, A. E., Baumann, T. F., & Orme, C. A. (2015) · ACS Nano · doi:10.1021/acsnano.5b00087 · Cited by 182
Cited by
A Review on MXene Synthesis, Stability, and Photocatalytic Applications
Murali, G., Reddy Modigunta, J. K., Park, Y. H., Lee, J.-H., Rawal, J., Lee, S.-Y., In, I., & Park, S.-J. (2022) · ACS Nano · doi:10.1021/acsnano.2c04750 · Cited by 668
Metadata
- Authors
- Chen, W. Y., Lai, S.-N., Yen, C.-C., Jiang, X., Peroulis, D., & Stanciu, L. A.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-08-28
- Volume
- 14
- Issue
- 9
- Pages
- 11490-11501
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W3081850727
- Cited by
- 446
- References
- 4
- FWCI
- 18.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surface Functionalization of Ti3C2Tx MXene with Highly Reliable Superhydrophobic Protection for Volatile Organic Compounds Sensing. https://app.cochat.ai/papers/10.1021/acsnano.0c03896
- The paper
- Chen, W. Y., Lai, S.-N., Yen, C.-C., Jiang, X., Peroulis, D., & Stanciu, L. A. (2020). Surface Functionalization of Ti3C2Tx MXene with Highly Reliable Superhydrophobic Protection for Volatile Organic Compounds Sensing. ACS Nano. https://doi.org/10.1021/acsnano.0c03896
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.