A Biodegradable and Recyclable Piezoelectric Sensor Based on a Molecular Ferroelectric Embedded in a Bacterial Cellulose Hydrogel
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Currently, various electronic devices make our life more and more safe, healthy, and comfortable, but at the same time, they produce a large amount of nondegradable and nonrecyclable electronic waste that threatens our environment. In this work, we explore an environmentally friendly and flexible mechanical sensor that is biodegradable and recyclable. The sensor consists of a bacterial cellulose (BC) hydrogel as the matrix and imidazolium perchlorate (ImClO 4 ) molecular ferroelectric as the functional element, the hybrid of which possesses a high sensitivity of 4 mV kPa –1 and a wide operational range from 0.2 to 31.25 kPa, outperforming those of most devices based on conventional functional biomaterials. Moreover, the BC hydrogel can be fully degraded into glucose and oligosaccharides, while ImClO 4 can be recyclable and reused for the same devices, leaving no environmentally hazardous electronic waste.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recovery of metals and nonmetals from electronic waste by physical and chemical recycling processes
Kaya, M. (2016) · Waste Management · doi:10.1016/j.wasman.2016.08.004 · Cited by 823
Nanomesh pressure sensor for monitoring finger manipulation without sensory interference
Lee, S., Franklin, S., Hassani, F. A., Yokota, T., Nayeem, M. O. G., Wang, Y., Leib, R., Cheng, G., Franklin, D. W., & Someya, T. (2020) · Science · doi:10.1126/science.abc9735 · Cited by 640
Self-citationMachine-knitted washable sensor array textile for precise epidermal physiological signal monitoring
Fan, W., He, Q., Meng, K., Tan, X., Zhou, Z., Zhang, G., Yang, J., & Wang, Z. L. (2020) · Science Advances · doi:10.1126/sciadv.aay2840 · Cited by 516
Self-citationA Flexible Bimodal Sensor Array for Simultaneous Sensing of Pressure and Temperature
Tien, N. T., Jeon, S., Kim, D., Trung, T. Q., Jang, M., Hwang, B., Byun, K., Bae, J., Lee, E., Tok, J. B. ‐., et al. (2014) · Advanced Materials · doi:10.1002/adma.201302869 · Cited by 438
Hierarchically patterned self-powered sensors for multifunctional tactile sensing
Wang, Y., Wu, H., Xu, L., Zhang, H., Yang, Y., & Wang, Z. L. (2020) · Science Advances · doi:10.1126/sciadv.abb9083 · Cited by 425
Self-citation
Cited by
Biodegradable Piezoelectric Polymers: Recent Advancements in Materials and Applications
Ali, M., Bathaei, M. J., Istif, E., Karimi, S. N. H., & Beker, L. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202300318 · Cited by 211
Nie, K., Zhang, X., Hu, Z., Zhang, X., Wang, L., Mei, L., & Wang, H. (2025) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.161038 · Cited by 14
Metadata
- Authors
- Lu, J., Hu, S., Li, W., Wang, X., Mo, X., Gong, X., Liu, H., Luo, W., Dong, W., Sima, C., Wang, Y., Yang, G., Luo, J.-T., Jiang, S., Shi, Z., & Zhang, G.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2022-03-02
- Volume
- 16
- Issue
- 3
- Pages
- 3744-3755
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W4214807519
- Cited by
- 200
- References
- 5
- FWCI
- 11.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.