Stretchable Unsymmetrical Piezoelectric BaTiO3 Composite Hydrogel for Triboelectric Nanogenerators and Multimodal Sensors

Wang, Zhuo, Liu, Zhirong, Zhao, Gengrui, Zhang, Zichao, Zhao, Xinyang, Wan, Xingyi, Zhang, Yalong, Wang, Zhong Lin, Li, Linlin·2022·ACS Nano

Abstract

Improving output performance of triboelectric nanogenerators (TENGs) is crucial for expanding their applications in smart devices, especially for flexible and wearable bioelectronics. In this study, we design and fabricate a flexible, stretchable, and highly transparent TENG based on an unsymmetrical PAM/BTO composite film, made of polyacrylamide (PAM) hydrogel and BaTiO 3 nanocubes (BTO NCs, BTO), and the TENG performance can be tailored by adjusting the amount and distribution location of BTO. The stretchable hydrogel electrode could bear over 8 times stretching. By changing the content and distribution location of BTO in the unsymmetrical hydrogel film, the output of the fabricated TENGs could be improved, acting as pressure sensors with high sensitivity to distinguish a spectrum of forces (0.25–6 N) at the low frequency. The mechanism of the enhanced output performance of the PAM/BTO composite hydrogel-based TENG is discussed in detail. By integrating piezoresistive, piezoelectric, and triboelectric effects, the optimized TENG and piezoresistive sensors are used as multimodal biomechanical sensors for detecting the motions of human bodies, pressure, and curvature with high sensitivity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsnano.1c10678

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 41 references

Cited by

See all 298

Metadata

Authors
Wang, Z., Liu, Z., Zhao, G., Zhang, Z., Zhao, X., Wan, X., Zhang, Y., Wang, Z. L., & Li, L.
Venue
ACS Nano
Published
2022-01-11
Volume
16
Issue
1
Pages
1661-1670
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W4205236326
Cited by
298
References
41
FWCI
17.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stretchable Unsymmetrical Piezoelectric BaTiO3 Composite Hydrogel for Triboelectric Nanogenerators and Multimodal Sensors. https://app.cochat.ai/papers/10.1021/acsnano.1c10678
The paper
Wang, Z., Liu, Z., Zhao, G., Zhang, Z., Zhao, X., Wan, X., Zhang, Y., Wang, Z. L., & Li, L. (2022). Stretchable Unsymmetrical Piezoelectric BaTiO3 Composite Hydrogel for Triboelectric Nanogenerators and Multimodal Sensors. ACS Nano. https://doi.org/10.1021/acsnano.1c10678

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.