The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Wirelessly Powered Electrical-Stimulation Based on Biodegradable 3D Piezoelectric Scaffolds Promotes the Spinal Cord Injury Repair
Abstract
An electroactive scaffold integrated with noninvasive in vivo electrical-stimulation (ES) capability shows great promise in the repair and regeneration of damaged tissues. Developing high-performance piezoelectric biomaterials which can simultaneously serve as both a biodegradable tissue scaffold and controllable electrical stimulator remains a great challenge. Herein, we constructed a biodegradable high-performance 3D piezoelectric scaffold with ultrasound (US)-driven wireless ES capability, and demonstrated its successful application for the repair of spinal cord injuries in a rat model. The 3D multichannel piezoelectric scaffold was prepared by electrospinning of poly(lactic acid) (PLA) nanofibers incorporated with biodegradable high-performance piezoelectric potassium sodium niobate (K 0.5 Na 0.5 NbO 3, KNN) nanowires. With programmed US irradiation as a remote mechanical stimulus, the on-demand in vivo ES with an adjustable timeline, duration, and strength can be delivered by the 3D piezoelectric scaffold. Under proper US excitation, the 3D tissue scaffolds made of the piezoelectric composite nanofibers can accelerate the recovery of motor functions and enhance the repair of spinal cord injury. The immunohistofluorescence investigation indicated that the 3D piezoelectric scaffolds combined with the US-driven in vivo ES promoted neural stem cell differentiation and endogenous angiogenesis in the lesion. This work highlights the potential application of a biodegradable high-performance piezoelectric scaffold providing US-driven on-demand electrical cues for regenerative medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradable triboelectric nanogenerator as a life-time designed implantable power source
Zheng, Q., Zou, Y., Zhang, Y., Liu, Z., Shi, B., Wang, X., Jin, Y., Ouyang, H., Li, Z., & Wang, Z. L. (2016) · Science Advances · doi:10.1126/sciadv.1501478 · Cited by 617
Fully Bioabsorbable Natural‐Materials‐Based Triboelectric Nanogenerators
Jiang, W., Li, H., Liu, Z., Li, Z., Tian, J., Shi, B., Zou, Y., Ouyang, H., Zhao, C., Zhao, L., et al. (2018) · Advanced Materials · doi:10.1002/adma.201801895 · Cited by 449
Cited by
Recent Advances in 3D Printing of Smart Scaffolds for Bone Tissue Engineering and Regeneration
Yuan, X., Zhu, W., Yang, Z., He, N., Chen, F., Han, X., & Zhou, K. (2024) · Advanced Materials · doi:10.1002/adma.202403641 · Cited by 339
Self-citation
Metadata
- Authors
- Chen, P., Xu, C., Wu, P., Liu, K., Chen, F., Chen, Y., Dai, H., & Luo, Z.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2022-09-29
- Volume
- 16
- Issue
- 10
- Pages
- 16513-16528
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W4297961869
- Cited by
- 228
- References
- 2
- FWCI
- 9.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.