Mechanically Robust and Linearly Sensitive Soft Piezoresistive Pressure Sensor for a Wearable Human–Robot Interaction System
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Soft piezoresistive pressure sensors play an underpinning role in enabling a plethora of future Internet of Things (IoT) applications such as human–robot interaction (HRI) technologies, wearable devices, and metaverse ecosystems. Despite significant attempts to enhance the performance of these sensors, existing sensors still fall short of achieving high strain tolerance and linearity simultaneously. Herein, we present a low-cost, facile, and scalable approach to fabricating a highly strain-tolerant and linearly sensitive soft piezoresistive pressure sensor. Our design utilizes thin nanocracked gold films (NC-GFs) deposited on poly(dimethylsiloxane) (PDMS) as electrodes of the sensor. The large mismatch stress between gold (Au) and PDMS induces the formation of secondary wrinkles along the pyramidal-structured electrode under pressure; these wrinkles function as protuberances on the electrode and enable exceptional linear sensitivity of 4.2 kPa –1 over a wide pressure range. Additionally, our pressure sensor can maintain its performance even after severe mechanical deformations, including repeated stretching up to 30% strain, due to the outstanding strain tolerance of NC-GF. Our sensor’s impressive sensing performance and mechanical robustness make it suitable for diverse IoT applications, as demonstrated by its use in wearable pulse monitoring devices and human–robot interaction systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electronic dura mater for long-term multimodal neural interfaces
Minev, I. R., Musienko, P., Hirsch, A., Barraud, Q., Wenger, N., Moraud, E. M., Gandar, J., Capogrosso, M., Milekovic, T., Asboth, L., et al. (2015) · Science · doi:10.1126/science.1260318 · Cited by 1,082
Skin-integrated wireless haptic interfaces for virtual and augmented reality
Yu, X., Xie, Z., Yu, Y., Lee, J., Vazquez-Guardado, A., Luan, H., Ruban, J., Ning, X., Akhtar, A., Li, D., et al. (2019) · Nature · doi:10.1038/s41586-019-1687-0 · Cited by 1,025
Self-citationFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Cited by
Cutting-Edge Perovskite-Based Flexible Pressure Sensors Made Possible by Piezoelectric Innovation
Naz, A., Meng, Y., Luo, J., Khan, I. A., Abbas, R., Yu, S., & Wei, J. (2024) · Materials · doi:10.3390/ma17174196 · Cited by 14
Metadata
- Authors
- Kim, S. W., Lee, J.-H., Ko, H. J., Lee, S., Bae, G. Y., Kim, D., Lee, G., Lee, S. G., & Cho, K.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2024-01-18
- Volume
- 18
- Issue
- 4
- Pages
- 3151-3160
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W4390975277
- Cited by
- 181
- References
- 3
- FWCI
- 19.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanically Robust and Linearly Sensitive Soft Piezoresistive Pressure Sensor for a Wearable Human–Robot Interaction System. https://app.cochat.ai/papers/10.1021/acsnano.3c09016
- The paper
- Kim, S. W., Lee, J.-H., Ko, H. J., Lee, S., Bae, G. Y., Kim, D., Lee, G., Lee, S. G., & Cho, K. (2024). Mechanically Robust and Linearly Sensitive Soft Piezoresistive Pressure Sensor for a Wearable Human–Robot Interaction System. ACS Nano. https://doi.org/10.1021/acsnano.3c09016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.