CoChat

Mechanically Robust and Linearly Sensitive Soft Piezoresistive Pressure Sensor for a Wearable Human–Robot Interaction System

Kim, Seong Won, Lee, Jeng-Hun, Ko, Hyeon Ju, Lee, Siyoung, Bae, Geun Yeol, Kim, Daegun, Lee, Giwon, Lee, Seung Goo, Cho, Kilwon · 2024 · ACS Nano
Cited by 181

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Soft piezoresistive pressure sensors play an underpinning role in enabling a plethora of future Internet of Things (IoT) applications such as human–robot interaction (HRI) technologies, wearable devices, and metaverse ecosystems. Despite significant attempts to enhance the performance of these sensors, existing sensors still fall short of achieving high strain tolerance and linearity simultaneously. Herein, we present a low-cost, facile, and scalable approach to fabricating a highly strain-tolerant and linearly sensitive soft piezoresistive pressure sensor. Our design utilizes thin nanocracked gold films (NC-GFs) deposited on poly(dimethylsiloxane) (PDMS) as electrodes of the sensor. The large mismatch stress between gold (Au) and PDMS induces the formation of secondary wrinkles along the pyramidal-structured electrode under pressure; these wrinkles function as protuberances on the electrode and enable exceptional linear sensitivity of 4.2 kPa –1 over a wide pressure range. Additionally, our pressure sensor can maintain its performance even after severe mechanical deformations, including repeated stretching up to 30% strain, due to the outstanding strain tolerance of NC-GF. Our sensor’s impressive sensing performance and mechanical robustness make it suitable for diverse IoT applications, as demonstrated by its use in wearable pulse monitoring devices and human–robot interaction systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsnano.3c09016

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 181

Metadata

Authors
Kim, S. W., Lee, J.-H., Ko, H. J., Lee, S., Bae, G. Y., Kim, D., Lee, G., Lee, S. G., & Cho, K.
Venue
ACS Nano
Published
2024-01-18
Volume
18
Issue
4
Pages
3151-3160
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W4390975277
Cited by
181
References
3
FWCI
19.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanically Robust and Linearly Sensitive Soft Piezoresistive Pressure Sensor for a Wearable Human–Robot Interaction System. https://app.cochat.ai/papers/10.1021/acsnano.3c09016
The paper
Kim, S. W., Lee, J.-H., Ko, H. J., Lee, S., Bae, G. Y., Kim, D., Lee, G., Lee, S. G., & Cho, K. (2024). Mechanically Robust and Linearly Sensitive Soft Piezoresistive Pressure Sensor for a Wearable Human–Robot Interaction System. ACS Nano. https://doi.org/10.1021/acsnano.3c09016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.