The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Near-Infrared Squaraine Dye Encapsulated Micelles for in Vivo Fluorescence and Photoacoustic Bimodal Imaging
Open accessAbstract
Combined near-infrared (NIR) fluorescence and photoacoustic imaging techniques present promising capabilities for noninvasive visualization of biological structures. Development of bimodal noninvasive optical imaging approaches by combining NIR fluorescence and photoacoustic tomography demands suitable NIR-active exogenous contrast agents. If the aggregation and photobleaching are prevented, squaraine dyes are ideal candidates for fluorescence and photoacoustic imaging. Herein, we report rational selection, preparation, and micelle encapsulation of an NIR-absorbing squaraine dye (D1) for in vivo fluorescence and photoacoustic bimodal imaging. D1 was encapsulated inside micelles constructed from a biocompatible nonionic surfactant (Pluoronic F-127) to obtain D1-encapsulated micelles (D1(micelle)) in aqueous conditions. The micelle encapsulation retains both the photophysical features and chemical stability of D1. D1(micelle) exhibits high photostability and low cytotoxicity in biological conditions. Unique properties of D1(micelle) in the NIR window of 800-900 nm enable the development of a squaraine-based exogenous contrast agent for fluorescence and photoacoustic bimodal imaging above 820 nm. In vivo imaging using D1(micelle), as demonstrated by fluorescence and photoacoustic tomography experiments in live mice, shows contrast-enhanced deep tissue imaging capability. The usage of D1(micelle) proven by preclinical experiments in rodents reveals its excellent applicability for NIR fluorescence and photoacoustic bimodal imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Batrakova, E. V., & Kabanov, A. V. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.04.013 · Cited by 1,278
Cited by
Contrast agents for molecular photoacoustic imaging
Weber, J., Beard, P. C., & Bohndiek, S. E. (2016) · Nature Methods · doi:10.1038/nmeth.3929 · Cited by 1,270
Photoacoustic Imaging: Contrast Agents and Their Biomedical Applications
Fu, Q., Zhu, R., Song, J., Yang, H., & Chen, X. (2019) · Advanced Materials · doi:10.1002/adma.201805875 · Cited by 681
Supramolecular cancer nanotheranostics
Zhou, J., Rao, L., Yu, G., Cook, T. R., Chen, X., & Huang, F. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00011f · Cited by 411
Qi, J., Chen, C., Zhang, X., Hu, X., Ji, S., Kwok, R. T. K., Lam, J. W. Y., Ding, D., & Tang, B. Z. (2018) · Nature Communications · doi:10.1038/s41467-018-04222-8 · Cited by 350
Organic Dye Based Nanoparticles for Cancer Phototheranostics
Cai, Y., Si, W., Huang, W., Chen, P., Shao, J., & Dong, X. (2018) · Small · doi:10.1002/smll.201704247 · Cited by 306
Metadata
- Authors
- Sreejith, S., Joseph, J., Lin, M., Menon, N. V., Borah, P., Ng, H. J., Loong, Y. X., Kang, Y., Yu, S. W.-K., & Zhao, Y.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-06-02
- Volume
- 9
- Issue
- 6
- Pages
- 5695-5704
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2268343952
- Cited by
- 168
- References
- 2
- FWCI
- 11.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.