The DOI matches its Crossref record.
Near-Infrared Light-Activatable Microneedle System for Treating Superficial Tumors by Combination of Chemotherapy and Photothermal Therapy
Abstract
Because of the aggressive and recurrent nature of cancers, repeated and multimodal treatments are often necessary. Traditional cancer therapies have a risk of serious toxicity and side effects. Hence, it is crucial to develop an alternative treatment modality that is minimally invasive, effectively treats cancers with low toxicity, and can be repeated as required. We developed a light-activatable microneedle (MN) system that can repeatedly and simultaneously provide photothermal therapy and chemotherapy to superficial tumors and exert synergistic anticancer effects. This system consists of embeddable polycaprolactone MNs containing a photosensitive nanomaterial (lanthanum hexaboride) and an anticancer drug (doxorubicin; DOX), and a dissolvable poly(vinyl alcohol)/polyvinylpyrrolidone supporting array patch. Because of this supporting array, the MNs can be completely inserted into the skin and embedded within the target tissue for locoregional cancer treatment. When exposed to near-infrared light, the embedded MN array uniformly heats the target tissue to induce a large thermal ablation area and then melts at 50 °C to release DOX in a broad area, thus destroying tumors. This light-activated heating and releasing behavior can be precisely controlled and switched on and off on demand for several cycles. We demonstrated that the MN-mediated synergistic therapy completely eradicated 4T1 tumors within 1 week after a single application of the MN and three cycles of laser treatment. No tumor recurrence and no significant body weight loss of mice were observed. Thus, the developed light-activatable MN with a unique embeddable feature offers an effective, user-friendly, and low-toxicity option for patients requiring long-term and multiple cancer treatments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Stimuli-responsive polymers and their applications
Wei, M., Gao, Y., Li, X., & Serpe, M. J. (2017) · Polymer Chemistry · doi:10.1039/c6py01585a · Cited by 1,298
Xia, Q., Zhang, Y., Li, Z., Hou, X., & Feng, N. (2019) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2019.01.011 · Cited by 665
Advances in transdermal insulin delivery
Zhang, Y., Yu, J., Kahkoska, A. R., Wang, J., Buse, J. B., & Gu, Z. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.12.006 · Cited by 325
Cardiac cell–integrated microneedle patch for treating myocardial infarction
Tang, J., Wang, J., Huang, K., Ye, Y., Su, T., Qiao, L., Hensley, M. T., Caranasos, T. G., Zhang, J., Gu, Z., et al. (2018) · Science Advances · doi:10.1126/sciadv.aat9365 · Cited by 316
Light: A Magical Tool for Controlled Drug Delivery
Tao, Y., Chan, H. F., Shi, B., Li, M., & Leong, K. W. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202005029 · Cited by 309
Metadata
- Authors
- Chen, M.-C., Lin, Z.-W., & Ling, M.-H.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-11-25
- Volume
- 10
- Issue
- 1
- Pages
- 93-101
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2410691776
- Cited by
- 358
- References
- 0
- FWCI
- 9.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Near-Infrared Light-Activatable Microneedle System for Treating Superficial Tumors by Combination of Chemotherapy and Photothermal Therapy. https://app.cochat.ai/papers/10.1021/acsnano.5b05043
- The paper
- Chen, M.-C., Lin, Z.-W., & Ling, M.-H. (2016). Near-Infrared Light-Activatable Microneedle System for Treating Superficial Tumors by Combination of Chemotherapy and Photothermal Therapy. ACS Nano. https://doi.org/10.1021/acsnano.5b05043
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.