The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Mid-Wave Infrared Photoconductors Based on Black Phosphorus-Arsenic Alloys
Open accessAbstract
Black phosphorus (b-P) and more recently black phosphorus-arsenic alloys (b-PAs) are candidate 2D materials for the detection of mid-wave and potentially long-wave infrared radiation. However, studies to date have utilized laser-based measurements to extract device performance and the responsivity of these detectors. As such, their performance under thermal radiation and spectral response has not been fully characterized. Here, we perform a systematic investigation of gated-photoconductors based on b-PAs alloys as a function of thickness over the composition range of 0–91% As. Infrared transmission and reflection measurements are performed to determine the bandgap of the various compositions. The spectrally resolved photoresponse for various compositions in this material system is investigated to confirm absorption measurements, and we find that the cutoff wavelength can be tuned from 3.9 to 4.6 μm over the studied compositional range. In addition, we investigated the temperature-dependent photoresponse and performed calibrated responsivity measurements using blackbody flood illumination. Notably, we find that the specific detectivity ( D *) can be optimized by adjusting the thickness of the b-P/b-PAs layer to maximize absorption and minimize dark current. We obtain a peak D * of 6 × 10 10 cm Hz 1/2 W –1 and 2.4 × 10 10 cm Hz 1/2 W –1 for pure b-P and b-PAs (91% As), respectively, at room temperature, which is an order of magnitude higher than commercially available mid-wave infrared detectors operating at room temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photodetectors based on graphene, other two-dimensional materials and hybrid systems
Koppens, F. H. L., Mueller, T., Avouris, P., Ferrari, A. C., Vitiello, M. S., & Polini, M. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.215 · Cited by 3,828
Cited by
Progress, Challenges, and Opportunities for 2D Material Based Photodetectors
Long, M., Wang, P., Fang, H., & Hu, W. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201803807 · Cited by 1,598
Recent Progress and Future Prospects of 2D‐Based Photodetectors
Huo, N., & Konstantatos, G. (2018) · Advanced Materials · doi:10.1002/adma.201801164 · Cited by 730
Bullock, J., Amani, M., Cho, J., Chen, Y.-Z., Ahn, G. H., Adinolfi, V., Shrestha, V. R., Gao, Y., Crozier, K. B., Chueh, Y.-L., et al. (2018) · Nature Photonics · doi:10.1038/s41566-018-0239-8 · Cited by 579
Self-citationLiang, S., Cheng, B., Cui, X., & Miao, F. (2020) · Advanced Materials · doi:10.1002/adma.201903800 · Cited by 537
Stable mid-infrared polarization imaging based on quasi-2D tellurium at room temperature
Tong, L., Huang, X., Wang, P., Ye, L., Peng, M., An, L., Sun, Q., Zhang, Y., Yang, G., Li, Z., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-16125-8 · Cited by 485
Metadata
- Authors
- Amani, M., Regan, E., Bullock, J., Ahn, G. H., & Javey, A.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-11-08
- Volume
- 11
- Issue
- 11
- Pages
- 11724-11731
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2765665974
- Cited by
- 243
- References
- 1
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.