The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Quantitative Assessment of Nanoparticle Biodistribution by Fluorescence Imaging, Revisited
Open accessAbstract
Fluorescence-based whole-body imaging is widely used in the evaluation of nanoparticles (NPs) in small animals, often combined with quantitative analysis to indicate their spatiotemporal distribution following systemic administration. An underlying assumption is that the fluorescence label represents NPs and the intensity increases with the amount of NPs and/or the labeling dyes accumulated in the region of interest. We prepare DiR-loaded poly(lactic- co-glycolic acid) (PLGA) NPs with different surface layers (polyethylene glycol with and without folate terminus) and compare the distribution of fluorescence signals in a mouse model of folate-receptor-expressing tumors by near-infrared fluorescence whole-body imaging. Unexpectedly, we observe that fluorescence distribution patterns differ far more dramatically with DiR loading than with the surface ligand, reaching opposite conclusions with the same type of NPs (tumor-specific delivery vs predominant liver accumulation). Analysis of DiR-loaded PLGA NPs reveals that fluorescence quenching, dequenching, and signal saturation, which occur with the increasing dye content and local NP concentration, are responsible for the conflicting interpretations. This study highlights the critical need for validating fluorescence labeling of NPs in the quantitative analysis of whole-body imaging. In light of our observation, we make suggestions for future whole-body fluorescence imaging in the in vivo evaluation of NP behaviors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescent Polymer Nanoparticles Based on Dyes: Seeking Brighter Tools for Bioimaging
Reisch, A., & Klymchenko, A. S. (2016) · Small · doi:10.1002/smll.201503396 · Cited by 634
Park, J., Pei, Y., Hyun, H., Castanares, M. A., Collins, D. S., & Yeo, Y. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.10.037 · Cited by 29
Self-citation
Cited by
Zhang, C., Yan, K., Fu, C., Peng, H., Hawker, C. J., & Whittaker, A. K. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00632 · Cited by 493
Qi, J., Hu, X., Dong, X., Lu, Y., Lu, H., Zhao, W., & Wu, W. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.05.009 · Cited by 292
Delivery of modified mRNA to damaged myocardium by systemic administration of lipid nanoparticles
Evers, M. J. W., Du, W., Yang, Q., Kooijmans, S. A. A., Vink, A., van Steenbergen, M., Vader, P., de Jager, S. C. A., Fuchs, S. A., Mastrobattista, E., et al. (2022) · Journal of Controlled Release · doi:10.1016/j.jconrel.2022.01.027 · Cited by 113
Zhang, H., Li, H., Cao, Z., Du, J., Yan, L., & Wang, J. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.04.046 · Cited by 45
Self-citation
Metadata
- Authors
- Meng, F., Wang, J., Ping, Q., & Yeo, Y.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-06-19
- Volume
- 12
- Issue
- 7
- Pages
- 6458-6468
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2808895931
- Cited by
- 182
- References
- 2
- FWCI
- 5.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative Assessment of Nanoparticle Biodistribution by Fluorescence Imaging, Revisited. https://app.cochat.ai/papers/10.1021/acsnano.8b02881
- The paper
- Meng, F., Wang, J., Ping, Q., & Yeo, Y. (2018). Quantitative Assessment of Nanoparticle Biodistribution by Fluorescence Imaging, Revisited. ACS Nano. https://doi.org/10.1021/acsnano.8b02881
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.