Cardiomyocyte-Driven Structural Color Actuation in Anisotropic Inverse Opals
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Biohybrid actuators composed of living tissues and artificial materials have attracted increasing interest in recent years because of their extraordinary function of dynamically sensing and interacting with complex bioelectrical signals. Here, a compound biohybrid actuator with self-driven actuation and self-reported feedback is designed based on an anisotropic inverse opal substrate with periodical elliptical macropores and a hydrogel filling. The benefit of the anisotropic surface topography and high biocompatibility of the hydrogel is that the planted cardiomyocytes could be induced into a highly ordered alignment with recovering autonomic beating ability on the elastic substrate. Because of the cell elongation and contraction during cardiomyocyte beating, the anisotropic inverse opal substrates undergo a synchronous cycle of deformation actuations, which can be reported as corresponding shifts of their photonic band gaps and structural colors. These self-driven biohybrid actuators could be used as elements for the construction of a soft-bodied structural color robot, such as a biomimetic guppy with a swinging tail. Besides, with the integration of a self-driven biohybrid actuator and microfluidics, the advanced heart-on-a-chip system with the feature of microphysiological visuality has been developed for integrated cell monitoring and drug testing. This anisotropic inverse opal-derived biohybrid actuator could be widely applied in biomedical engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Instrumented cardiac microphysiological devices via multimaterial three-dimensional printing
Lind, J. U., Busbee, T. A., Valentine, A. D., Pasqualini, F. S., Yuan, H., Yadid, M., Park, S.-J., Kotikian, A., Nesmith, A. P., Campbell, P. H., et al. (2017) · Nature Materials · doi:10.1038/nmat4782 · Cited by 863
Cells Cultured on Core–Shell Photonic Crystal Barcodes for Drug Screening
Fu, F., Shang, L., Zheng, F., Chen, Z., Wang, H., Wang, J., Gu, Z., & Zhao, Y. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b04966 · Cited by 118
Self-citation
Cited by
Bioinspired Synergistic Fluorescence‐Color‐Switchable Polymeric Hydrogel Actuators
Wei, S., Lu, W., Le, X., Ma, C., Lin, H., Wu, B., Zhang, J., Theato, P., & Chen, T. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201908437 · Cited by 303
Transformer Hydrogels: A Review
Erol, O., Pantula, A., Liu, W., & Gracias, D. H. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900043 · Cited by 293
Sensors-integrated organ-on-a-chip for biomedical applications
Chen, H., Luo, Z., Lin, X., Zhu, Y., & Zhao, Y. (2023) · Nano Research · doi:10.1007/s12274-023-5651-9 · Cited by 47
Self-citationHierarchical Hydrogels with Ordered Micro-Nano Structures for Cancer-on-a-Chip Construction
Zhu, L., Shao, C., Chen, H., Chen, Z., & Zhao, Y. (2021) · Research · doi:10.34133/2021/9845679 · Cited by 41
“SiO2 nanoparticles were self-prepared through the Stöber method, and methacrylate gelatin (GelMA) was self-synthesized from gelatin [40].”
MethodSelf-citationBiohybrid Response Microparticles Decorated with Trained‐MSCs for Acute Liver Failure Recovery
Wang, J., Huang, D., Yu, H., Ren, H., & Shang, L. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202201085 · Cited by 28
Metadata
- Authors
- Shang, Y., Chen, Z., Fu, F., Sun, L., Shao, C., Jin, W., Liu, H., & Zhao, Y.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-12-19
- Volume
- 13
- Issue
- 1
- Pages
- 796-802
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2905191227
- Cited by
- 128
- References
- 2
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.