The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Dynamically Stretchable Supercapacitor for Powering an Integrated Biosensor in an All-in-One Textile System
Abstract
Textile-based electronics have attracted much attention as they can perfectly combine the functionality of wearable devices with the soft and comfortable properties of flexible textile fibers. In this work, we report a dynamically stretchable high-performance supercapacitor for powering an integrated sensor in an all-in-one textile system to detect various biosignals. The supercapacitor fabricated with MWCNT/MoO 3 nanocomposite electrodes and nonaqueous gel electrolyte, along the course direction of the fabric, exhibits stable and high electrochemical performance under dynamic and static deformation, including stretching in real time, regardless of the strain rate. The strain sensor created along the wale direction of the fabric shows a high sensitivity of 46.3 under an applied strain up to 60%, a fast response time of 50 ms, and high stability over 10 000 cycles of stretching/releasing. Finally, the supercapacitor and strain sensor are integrated into an all-in-one textile system via liquid-metal interconnections, and the sensor is powered by the stored energy in the supercapacitor. This system sewed into cloth successfully detects strain due to joint movement and the wrist pulse. This work demonstrates the high feasibility of utilizing the fabricated stretchable all-in-one textile system for real-time health monitoring in everyday wearable devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Trung, T. Q., Ramasundaram, S., Hwang, B., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504441 · Cited by 870
Graphene Textile Strain Sensor with Negative Resistance Variation for Human Motion Detection
Yang, Z., Pang, Y., Han, X.-L., Yang, Y., Ling, J., Jian, M., Zhang, Y., Yang, Y., & Ren, T.-L. (2018) · ACS Nano · doi:10.1021/acsnano.8b03391 · Cited by 563
Kim, D., Kim, D., Lee, H., Jeong, Y. R., Lee, S., Yang, G., Kim, H., Lee, G., Jeon, S., Zi, G., et al. (2016) · Advanced Materials · doi:10.1002/adma.201504335 · Cited by 148
Self-citation
Cited by
Flexible/Stretchable Supercapacitors with Novel Functionality for Wearable Electronics
Keum, K., Kim, J. W., Hong, S. Y., Son, J. G., Lee, S., & Ha, J. S. (2020) · Advanced Materials · doi:10.1002/adma.202002180 · Cited by 492
Self-citationZhang, X., Wang, X., Lei, Z., Wang, L., Tian, M., Zhu, S., Xiao, H., Tang, X., & Qu, L. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c01182 · Cited by 358
Cheng, T., Zhang, Y., Wang, S., Chen, Y., Gao, S., Wang, F., Lai, W., & Huang, W. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202101303 · Cited by 308
Metadata
- Authors
- Park, H., Kim, J. W., Hong, S. Y., Lee, G., Lee, H., Song, C., Keum, K., Jeong, Y. R., Jin, S. W., Kim, D. S., & Ha, J. S.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-08-28
- Volume
- 13
- Issue
- 9
- Pages
- 10469-10480
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2970535130
- Cited by
- 158
- References
- 4
- FWCI
- 6.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamically Stretchable Supercapacitor for Powering an Integrated Biosensor in an All-in-One Textile System. https://app.cochat.ai/papers/10.1021/acsnano.9b04340
- The paper
- Park, H., Kim, J. W., Hong, S. Y., Lee, G., Lee, H., Song, C., Keum, K., Jeong, Y. R., Jin, S. W., Kim, D. S., & Ha, J. S. (2019). Dynamically Stretchable Supercapacitor for Powering an Integrated Biosensor in an All-in-One Textile System. ACS Nano. https://doi.org/10.1021/acsnano.9b04340
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.