Rapid Fabrication of Poly(methyl methacrylate) Devices for Lab-on-a-Chip Applications Using Acetic Acid and UV Treatment
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In the present study, we introduce a new approach for rapid bonding of poly(methyl methacrylate) (PMMA)-based microdevices using an acetic acid solvent with the assistance of UV irradiation. For the anticipated mechanism, acetic acid and UV irradiation induced free radicals on the PMMA surfaces, and acrylate monomers subsequently formed cross-links to create a permanent bonding between the PMMA substrates. PMMA devices effectively bonded within 30 s at a low pressure using clamps, and a clogging-free microchannel was achieved with the optimized 50% acetic acid. For surface characterizations, contact angle measurements and bonding performance analyses were conducted using predetermined acetic acid concentrations to optimize bonding conditions. In addition, the highest bond strength of bonded PMMA was approximately 11.75 MPa, which has not been reported before in the bonding of PMMA. A leak test was performed over 180 h to assess the robustness of the proposed method. Moreover, to promote the applicability of this bonding method, we tested two kinds of microfluidic device applications, including a cell culture-based device and a metal microelectrode-integrated device. The results showed that the cell culture-based application was highly biocompatible with the PMMA microdevices fabricated using an acetic acid solvent. Moreover, the low pressure required during the bonding process supported the integration of metal microelectrodes with the PMMA microdevice without any damage to the metal films. This novel bonding method holds great potential in the ecofriendly and rapid fabrication of microfluidic devices using PMMA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nguyen, T., Jung, S. H., Lee, M. S., Park, T.-E., Ahn, S.-K., & Kang, J. H. (2019) · Lab on a Chip · doi:10.1039/c9lc00338j · Cited by 77
Cited by
Surface Modification Techniques for Endothelial Cell Seeding in PDMS Microfluidic Devices
Akther, F., Yakob, S. B., Nguyen, N.-T., & Ta, H. T. (2020) · Biosensors · doi:10.3390/bios10110182 · Cited by 182
Skin models of cutaneous toxicity, transdermal transport and wound repair
Vilela de Sousa, I., Ferreira, M. J. S., Bebiano, L. B., Simões, S., Matos, A. F., Pereira, R. F., & Granja, P. L. (2023) · Burns & Trauma · doi:10.1093/burnst/tkad014 · Cited by 17
“PMMA is mainly used in microfluidics due to its easy processability, cost-effectiveness, optical transparency and biocompatibility [171].”
Background
Metadata
- Authors
- Trinh, K. T. L., Thai, D. A., Chae, W. R., & Lee, N. Y.
- Venue
- ACS Omega
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-07-08
- Volume
- 5
- Issue
- 28
- Pages
- 17396-17404
- ISSN
- 2470-1343 (ISSN-L)
- OpenAlex
- W3041818234
- Cited by
- 67
- References
- 1
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid Fabrication of Poly(methyl methacrylate) Devices for Lab-on-a-Chip Applications Using Acetic Acid and UV Treatment. https://app.cochat.ai/papers/10.1021/acsomega.0c01770
- The paper
- Trinh, K. T. L., Thai, D. A., Chae, W. R., & Lee, N. Y. (2020). Rapid Fabrication of Poly(methyl methacrylate) Devices for Lab-on-a-Chip Applications Using Acetic Acid and UV Treatment. ACS Omega. https://doi.org/10.1021/acsomega.0c01770
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.