The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Self-Assembled Polyvinyl Alcohol–Tannic Acid Hydrogels with Diverse Microstructures and Good Mechanical Properties
Open accessAbstract
Fabrication of hydrogels with unique microstructures and better mechanical properties through the self-assembly of commercially available synthetic polymers and small molecules is of great scientific and practical importance. A type of physical hydrogels is prepared by the self-assembly of polyvinyl alcohol (PVA) and tannic acid (TA) in aqueous solution with a low PVA-TA concentration (0.5-6.0 wt %) at room temperature. With the increase of the PVA-TA concentration, the water content of the hydrogels increases, and the content of TA in the hydrogels decreases from 23.1 to 6.4%. The driving force for the self-assembly is proven to be the hydrogen bonding between PVA and TA, which also induces the crystallization of PVA chains. The self-assembled PVA-TA hydrogels have diverse morphologies that change from microspheres to oriented porous structures with the increase of the PVA-TA concentration, and these structures are all composed of nanosized particles, fibers, and/or sheets. Most of the self-assembled PVA-TA hydrogels show good mechanical properties. The highest tensile strength and elastic modulus of the PVA-TA hydrogel prepared with 1.0 wt % PVA-TA concentration are about 84 and 30 kPa, respectively. This self-assembly method would lead to the fabrication of more hydrogels with unique microstructures and properties for practical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels for biomedical applications
Hoffman, A. S. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00239-3 · Cited by 4,864
Hydrogels for biomedical applications
Hoffman, A. S. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.010 · Cited by 3,396
Self-Assembled Graphene Hydrogel via a One-Step Hydrothermal Process
Xu, Y., Sheng, K., Li, C., & Shi, G. (2010) · ACS Nano · doi:10.1021/nn101187z · Cited by 3,251
Cited by
Ahmadian, Z., Correia, A., Hasany, M., Figueiredo, P., Dobakhti, F., Eskandari, M. R., Hosseini, S. H., Abiri, R., Khorshid, S., Hirvonen, J., et al. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202001122 · Cited by 351
Engineering Smart Composite Hydrogels for Wearable Disease Monitoring
Li, J., Ding, Q., Wang, H., Wu, Z., Gui, X., Li, C., Hu, N., Tao, K., & Wu, J. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01079-5 · Cited by 304
Self-citationRecent advances in tannic acid-based gels: Design, properties, and applications
Tang, Z., Chowdhury, I. F., Yang, J., Li, S., Mondal, A. K., & Wu, H. (2025) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2025.103425 · Cited by 70
Fabrication of innocuous hydrogel scaffolds based on modified dextran for biotissues
Kang, D.-S., Yang, S.-Y., & Lee, C.-Y. (2022) · Carbohydrate Research · doi:10.1016/j.carres.2022.108699 · Cited by 6
Metadata
- Authors
- Chen, Y.-N., Jiao, C., Zhao, Y., Zhang, J., & Wang, H.
- Venue
- ACS Omega
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-09-24
- Volume
- 3
- Issue
- 9
- Pages
- 11788-11795
- ISSN
- 2470-1343 (ISSN-L)
- OpenAlex
- W2893649743
- Cited by
- 203
- References
- 3
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.