Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 187

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

High-Responsivity Deep-Ultraviolet-Selective Photodetectors Using Ultrathin Gallium Oxide Films

Lee, Seung Hyun, Kim, Soo Bin, Moon, Yoon-Jong, Kim, Sung Min, Jung, Hae Jun, Seo, Myung Su, Lee, Kang Min, Kim, Sun-Kyung, Lee, Sang Woon·2017·ACS Photonics

Abstract

Wavelength-selective photodetectors responding to deep-ultraviolet (DUV) wavelengths (λ = 200–300 nm) are drawing significant interest in diverse sensing applications, ranging from micrometer biological molecules to massive military missiles. However, most DUV photodetectors developed thus far have suffered from long response times, low sensitivity, and high processing temperatures, impeding their practical use. Here, we report fast, high-responsivity, and general-substrate-compatible DUV photodetectors based on ultrathin (3–50 nm) amorphous gallium oxide (GaO X ) films grown by low-temperature (∼<250 °C) atomic layer deposition (ALD) for the first time. ALD-grown GaO X films on glass substrates display a typical amorphous nature, which is identified by electron beam diffraction and X-ray diffraction measurements, while their band gap is sharply featured at ∼4.8 eV. Metal–semiconductor–metal photodetectors (active area of 30 × 30 μm 2 ) using the 30-nm-thick GaO X films work reliably only for DUV wavelengths; the responsivity is maximized to 45.11 A/W at λ = 253 nm, which dropped off at λ ≈ 300 nm (i.e., a cutoff wavelength). The dark current measured at 10 V is as low as 200 pA and the signal-to-noise ratio reaches up to ∼10 4, underpinning the pristine material quality of the ALD-grown GaO X films. In addition, the rise time (i.e., the time interval for photocurrent to increase from 10% to 90%) is as quick as 2.97 μs at λ = 266 nm. Such a reliable and fast photoresponse is achieved for even atomically thin (∼3 nm) devices. The substrate-compatible and low-temperature ALD growth permits the demonstration of flexible DUV photodetectors using amorphous GaO X films grown on polyimide substrates, suggesting their facile integration into other curved optoelectronic systems. We believe that photodetectors developed herein will provide an economically viable solution for high-performance DUV detection and create a variety of sensing applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsphotonics.7b01054

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Metadata

Authors
Lee, S. H., Kim, S. B., Moon, Y.-J., Kim, S. M., Jung, H. J., Seo, M. S., Lee, K. M., Kim, S.-K., & Lee, S. W.
Venue
ACS Photonics
Published
2017-10-20
Volume
4
Issue
11
Pages
2937-2943
ISSN
2330-4022 (ISSN-L)
OpenAlex
W2763353910
Cited by
187
References
1
FWCI
5.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.