The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Self-Powered Monitoring of Ammonia Using an MXene/TiO2/Cellulose Nanofiber Heterojunction-Based Sensor Driven by an Electrospun Triboelectric Nanogenerator
Abstract
Real-time monitoring of harmful gases is of great significance to identify the environmental hazards to people’s lives. However, this application scenario requiring low-power consumption, superior sensitivity, portability, and self-driven operation of gas sensors remains a challenge. Herein, an electrospun triboelectric nanogenerator (TENG) is synthesized using highly electronegative and conducting MXene nanofibers (NFs) paired with biodegradable cellulose acetate NFs (CA-NFs) as triboelectric layers, which supports a sufficient power density (∼1361 mW/m 2 @2 MΩ) and shows a self-powered ability to operate the chemiresistive gas sensor fabricated in this work. Further, by using cellulose nanofibers (C-NFs) as a substrate, a new kind of MXene/TiO 2 /C-NFs heterojunction-based sensory component is developed for detection of NH 3 . This sensor exhibits excellent reproducibility, high selectivity, and sensitivity toward NH 3 (1–100 ppm) along with a fast response/recovery time (76 s/62 s) at room temperature. Finally, a monitoring system comprising a TENG-powered sensor, an equivalent circuit, and an LED visualizer has been assembled and successfully demonstrated as a fully self-powered device for NH 3 leakage detection. Thus, this work pushes forward the intelligent gas sensing network self-driven by human motion energy, dispensing the external battery dependence for environment monitoring to reduce the possible health effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metallic Ti3C2T x MXene Gas Sensors with Ultrahigh Signal-to-Noise Ratio
Kim, S. J., Koh, H.-J., Ren, C. E., Kwon, O., Maleski, K., Cho, S.-Y., Anasori, B., Kim, C.-K., Choi, Y.-K., Kim, J., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07460 · Cited by 1,699
Room Temperature Gas Sensing of Two-Dimensional Titanium Carbide (MXene)
Lee, E., VahidMohammadi, A., Prorok, B. C., Yoon, Y. S., Beidaghi, M., & Kim, D.-J. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b11055 · Cited by 878
Cited by
Electrospun nanofiber based TENGs for wearable electronics and self-powered sensing
Babu, A., Aazem, I., Walden, R., Bairagi, S., Mulvihill, D. M., & Pillai, S. C. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.139060 · Cited by 293
Metadata
- Authors
- Sardana, S., Kaur, H., Arora, B., Aswal, D. K., & Mahajan, A.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2022-01-14
- Volume
- 7
- Issue
- 1
- Pages
- 312-321
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W4206309179
- Cited by
- 212
- References
- 2
- FWCI
- 12.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.