Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 243

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Fully Flexible MXene-based Gas Sensor on Paper for Highly Sensitive Room-Temperature Nitrogen Dioxide Detection

Quan, Wenjing, Shi, Jia, Luo, Hanyu, Fan, Chao, Lv, Wen, Chen, Xinwei, Zeng, Min, Yang, Jianhua, Hu, Nantao, Su, Yanjie, Wei, Hao, Yang, Zhi · 2023 · ACS Sensors

Abstract

Flexible chemiresistive gas sensors have attracted growing interest due to their capability in real-time and rapid detection of gas. However, the performance of gas sensors has long been hindered by the poor charge transfer ability between the conventional metal electrode and gas sensing semiconductors. Herein, for the first time, a fully flexible paper-based gas sensor integrated with the Ti 3 C 2 T x -MXene nonmetallic electrode and the Ti 3 C 2 T x /WS 2 gas sensing film was designed to form Ohmic contact and Schottky heterojunction in a single gas sensing channel. Ti 3 C 2 T x /WS 2 has outstanding physical and chemical properties for both Ti 3 C 2 T x and WS 2 nanoflakes, showing high conductivity, effective charge transfer, and abundant active sites for gas sensing. The response of the gas sensor to NO 2 (1 ppm) at room temperature is 15.2%, which is about 3.2 and 76.0 times as high as that of the Au interdigital electrode integrated with the Ti 3 C 2 T x /WS 2 sensor (4.8%) and the MXene electrode integrated with the Ti 3 C 2 T x sensor (0.2%), respectively. Besides, this design performed at a limit of detection with 11.0 ppb NO 2 gas and displayed excellent stability under high humidities. Based on first-principles density functional theory calculation results, the improvement of the gas sensing performance can be mainly attributed to the heterojunction regulation effect, work function matching, and suppressing metal-induced gap states. This work provides a new approach for the design of flexible gas sensors on paper with MXene-based conductive electrodes and gas sensing materials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acssensors.2c01748

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 243

Metadata

Authors
Quan, W., Shi, J., Luo, H., Fan, C., Lv, W., Chen, X., Zeng, M., Yang, J., Hu, N., Su, Y., Wei, H., & Yang, Z.
Venue
ACS Sensors
Published
2023-01-13
Volume
8
Issue
1
Pages
103-113
ISSN
2379-3694 (ISSN-L)
OpenAlex
W4315797514
Cited by
243
References
4
FWCI
17.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.