Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Self-powered ultra-flexible electronics via nano-grating-patterned organic photovoltaics

Abstract

Next-generation biomedical devices 1-9 will need to be self-powered and conformable to human skin or other tissue. Such devices would enable the accurate and continuous detection of physiological signals without the need for an external power supply or bulky connecting wires. Self-powering functionality could be provided by flexible photovoltaics that can adhere to moveable and complex three-dimensional biological tissues 1-4 and skin 5-9 . Ultra-flexible organic power sources 10-13 that can be wrapped around an object have proven mechanical and thermal stability in long-term operation 13 , making them potentially useful in human-compatible electronics. However, the integration of these power sources with functional electric devices including sensors has not yet been demonstrated because of their unstable output power under mechanical deformation and angular change. Also, it will be necessary to minimize high-temperature and energy-intensive processes 10,12 when fabricating an integrated power source and sensor, because such processes can damage the active material of the functional device and deform the few-micrometre-thick polymeric substrates. Here we realize self-powered ultra-flexible electronic devices that can measure biometric signals with very high signal-to-noise ratios when applied to skin or other tissue. We integrated organic electrochemical transistors used as sensors with organic photovoltaic power sources on a one-micrometre-thick ultra-flexible substrate. A h…

Overview

Integrity signals

Registry

Crossref · 10.1038/s41586-018-0536-x

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 30 references

Research works printed but not linked: 1

  1. Orphanidou, C. Signal Quality Assessment in Physiological Monitoring: State of the Art and Practical Considerations (Springer, Cham, 2017).

Cited by

See all 1,068

Metadata

Authors
Park, S., Heo, S. W., Lee, W., Inoue, D., Jiang, Z., Yu, K., Jinno, H., Hashizume, D., Sekino, M., Yokota, T., Fukuda, K., Tajima, K., & Someya, T.
Affiliations
  • Samsung (South Korea) (KR)
  • RIKEN (JP)
  • The University of Tokyo (JP)
Corresponding author
  • Fukuda, Kenjiro
  • Tajima, Keisuke
  • Someya, Takao
Venue
Nature
Published
2018-09-26
Volume
561
Issue
7724
Pages
516-521
ISSN
  • 0028-0836 (ISSN-L)
  • 1476-4687
OpenAlex
W2891386968
Cited by
1,068
References
30
Citations by year
2026: 70 · 2025: 113 · 2024: 174 · 2023: 151 · 2022: 154 · 2021: 164 · 2020: 148 · 2019: 90 · 2018: 3
FWCI
40.45
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • Nature (publishedVersion)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
Funders
  • Toray Industries
  • Japan Society for the Promotion of Science (18J12791)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Organic Electronics and Photovoltaics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
Keywords
self-powered devices, organic solar cells, organic electrochemical transistors, charge transport layers, power conversion efficiency, flexible power sources
MeSH terms
Hemodynamic Monitoring, Animals, Electronics, Hot Temperature, Humans, Male, Monitoring, Physiologic, Polymers, Electric Power Supplies, Transistors, Electronic, Pliability, Nanotechnology, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Self-powered ultra-flexible electronics via nano-grating-patterned organic photovoltaics. https://app.cochat.ai/papers/10.1038/s41586-018-0536-x
The paper
Park, S., Heo, S. W., Lee, W., Inoue, D., Jiang, Z., Yu, K., Jinno, H., Hashizume, D., Sekino, M., Yokota, T., Fukuda, K., Tajima, K., & Someya, T. (2018). Self-powered ultra-flexible electronics via nano-grating-patterned organic photovoltaics. Nature. https://doi.org/10.1038/s41586-018-0536-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.