The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly Selective Turn-On Fluorogenic Chemosensor for Robust Quantification of Zn(II) Based on Aggregation Induced Emission Enhancement Feature
Abstract
An incisively designed notable aggregation-induced emission enhancement (AIEE) active fluorescence probe, 1-(2-hydroxynaphthylmethylene)-2-(3-methoxy-2-hydroxybenzylidene) hydrazine (L), was synthesized via straightforward reaction from inexpensive reagents. It exhibited rapid response, superb selectivity, and swift sensitivity toward Zn 2+ based on its promising CHEF/AIEE feature. L not only can sense Zn 2+ through sharp colorimetric and selective turn-on fluorescence responses in DMF/H 2 O (9:1, v/v) medium, but also can distinguish between its significant AIEE activity in high water ratio and Zn 2+ triggered AIEE activity through individual emission signals. Intriguingly, the AIEE properties of L may improve its impact. The molecules of L are aggregated into ordered one-dimensional rod-shaped microcrystals that show an obvious optical waveguide effect. Job’s plot from UV–vis absorption revealed the formation of L-Zn 2+ complex with 1:1 stoichiometry. When bound with Zn 2+ in 1:1 mode, enhanced turn-on emission was observed via chelation enhanced fluorescence through sensor complex (L-Zn) formation and excess addition of Zn 2+, a vivid enhancement of fluorescence intensity over manifold through aggregate formation was observed. The entire process takes ∼5 s, i.e., faster response time. The probe can detect Zn 2+ as low as 1.1 × 10 –7 M. The AIEE mechanism of L and Zn 2+ triggered AIEE mechanism were well established from fluorescence anisotropy, DLS, SEM, optical fluorescence microscope, time-resolved photoluminescence, and fluorescence reversibility study by adding Zn 2+ and EDTA sequentially. Furthermore, the proposed analytical system with clear AIEE mechanism demonstrates a potential outlook for the on-site practical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hong, Y., Lam, J. W. Y., & Tang, B. Z. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15113d · Cited by 6,363
Cited by
Fluorescent Sensors Based on Aggregation-Induced Emission: Recent Advances and Perspectives
Gao, M., & Tang, B. Z. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00551 · Cited by 666
AIE-based luminescence probes for metal ion detection
Alam, P., Leung, N. L. C., Zhang, J., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213693 · Cited by 275
Metadata
- Authors
- Shyamal, M., Mazumdar, P., Maity, S., Samanta, S., Sahoo, G. P., & Misra, A.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-05-11
- Volume
- 1
- Issue
- 6
- Pages
- 739-747
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W2345761110
- Cited by
- 210
- References
- 1
- FWCI
- 12.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.