Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 210

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Highly Selective Turn-On Fluorogenic Chemosensor for Robust Quantification of Zn(II) Based on Aggregation Induced Emission Enhancement Feature

Shyamal, Milan, Mazumdar, Prativa, Maity, Samir, Samanta, Sadhan, Sahoo, Gobinda P., Misra, Ajay · 2016 · ACS Sensors

Abstract

An incisively designed notable aggregation-induced emission enhancement (AIEE) active fluorescence probe, 1-(2-hydroxynaphthylmethylene)-2-(3-methoxy-2-hydroxybenzylidene) hydrazine (L), was synthesized via straightforward reaction from inexpensive reagents. It exhibited rapid response, superb selectivity, and swift sensitivity toward Zn 2+ based on its promising CHEF/AIEE feature. L not only can sense Zn 2+ through sharp colorimetric and selective turn-on fluorescence responses in DMF/H 2 O (9:1, v/v) medium, but also can distinguish between its significant AIEE activity in high water ratio and Zn 2+ triggered AIEE activity through individual emission signals. Intriguingly, the AIEE properties of L may improve its impact. The molecules of L are aggregated into ordered one-dimensional rod-shaped microcrystals that show an obvious optical waveguide effect. Job’s plot from UV–vis absorption revealed the formation of L-Zn 2+ complex with 1:1 stoichiometry. When bound with Zn 2+ in 1:1 mode, enhanced turn-on emission was observed via chelation enhanced fluorescence through sensor complex (L-Zn) formation and excess addition of Zn 2+, a vivid enhancement of fluorescence intensity over manifold through aggregate formation was observed. The entire process takes ∼5 s, i.e., faster response time. The probe can detect Zn 2+ as low as 1.1 × 10 –7 M. The AIEE mechanism of L and Zn 2+ triggered AIEE mechanism were well established from fluorescence anisotropy, DLS, SEM, optical fluorescence microscope, time-resolved photoluminescence, and fluorescence reversibility study by adding Zn 2+ and EDTA sequentially. Furthermore, the proposed analytical system with clear AIEE mechanism demonstrates a potential outlook for the on-site practical applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acssensors.6b00289

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 210

Metadata

Authors
Shyamal, M., Mazumdar, P., Maity, S., Samanta, S., Sahoo, G. P., & Misra, A.
Venue
ACS Sensors
Published
2016-05-11
Volume
1
Issue
6
Pages
739-747
ISSN
2379-3694 (ISSN-L)
OpenAlex
W2345761110
Cited by
210
References
1
FWCI
12.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.