The DOI matches its Crossref record; 92 of the 92 references it cites were found in a registry or an index.
Self-Powered Biosensors
Abstract
Self-powered electrochemical biosensors utilize biofuel cells as a simultaneous power source and biosensor, which simplifies the biosensor system, because it no longer requires a potentiostat, power for the potentiostat, and/or power for the signaling device. This review article is focused on detailing the advances in the field of self-powered biosensors and discussing their advantages and limitations compared to other types of electrochemical biosensors. The review will discuss self-powered biosensors formed from enzymatic biofuel cells, organelle-based biofuel cells, and microbial fuel cells. It also discusses the different mechanisms of sensing, including utilizing the analyte being the substrate/fuel for the biocatalyst, the analyte binding the biocatalyst to the electrode surface, the analyte being an inhibitor of the biocatalyst, the analyte resulting in the blocking of the bioelectrocatalytic response, the analyte reactivating the biocatalyst, Boolean logic gates, and combining affinity-based biorecognition elements with bioelectrocatalytic power generation. The final section of this review details areas of future investigation that are needed in the field, as well as problems that still need to be addressed by the field.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Wearable biofuel cells, in particular, are promising for the powering of non-invasive wearable platforms as they harvest energy from the same biofluids of interest and can operate as self-powered biosensors, but yet still suffer from the same stability issues discussed above42,193,194.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [194]
In the citing paper
“Wearable biofuel cells, in particular, are promising for the powering of non-invasive wearable platforms as they harvest energy from the same biofluids of interest and can operate as self-powered biosensors, but yet still suffer from the same stability issues discussed above42,193,194.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [194]
In the citing paper
“Wearable biofuel cells, in particular, are promising for the powering of non-invasive wearable platforms as they harvest energy from the same biofluids of interest and can operate as self-powered biosensors, but yet still suffer from the same stability issues discussed above42,193,194.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [194]
In the citing paper
“Wearable biofuel cells, in particular, are promising for the powering of non-invasive wearable platforms as they harvest energy from the same biofluids of interest and can operate as self-powered biosensors, but yet still suffer from the same stability issues discussed above42,193,194.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [194]
Citations
Cites
Challenges in biocatalysis for enzyme-based biofuel cells
Kim, J., Jia, H., & Wang, P. (2006) · Biotechnology Advances · doi:10.1016/j.biotechadv.2005.11.006 · Cited by 555
Enzyme-based logic systems for information processing
Katz, E., & Privman, V. (2010) · Chemical Society Reviews · doi:10.1039/b806038j · Cited by 511
Enzymatic biofuel cells: 30 years of critical advancements
Rasmussen, M., Abdellaoui, S., & Minteer, S. D. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.029 · Cited by 497
Self-citationSelf-Powered Enzyme-Based Biosensors
Katz, E. Y., Bückmann, A. F., & Willner, I. (2001) · Journal of the American Chemical Society · doi:10.1021/ja0167102 · Cited by 491
Continuous determination of biochemical oxygen demand using microbial fuel cell type biosensor
Chang, I. S., Jang, J., Gil, G. C., Kim, M., Kim, H. J., Cho, B. W., & Kim, B. H. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00272-0 · Cited by 415
Novel BOD (biological oxygen demand) sensor using mediator-less microbial fuel cell
Kim, B. H., Chang, I. S., Gil, G. C., Park, H. S., & Kim, H. J. (2003) · Biotechnology Letters · doi:10.1023/a:1022891231369 · Cited by 394
Integrated Enzyme‐Based Biofuel Cells–A Review
Willner, I., Yan, Y., Willner, B. I., & Tel‐Vered, R. (2009) · Fuel Cells · doi:10.1002/fuce.200800115 · Cited by 378
Microbial electrode BOD sensors
Karube, I., Matsunaga, T., Mitsuda, S., & Suzuki, S. (1977) · Biotechnology and Bioengineering · doi:10.1002/bit.260191010 · Cited by 362
Extended lifetime biofuel cells
Moehlenbrock, M. J., & Minteer, S. D. (2008) · Chemical Society Reviews · doi:10.1039/b708013c · Cited by 351
Self-citationStretchable biofuel cells as wearable textile-based self-powered sensors
Jeerapan, I., Sempionatto, J. R., Pavinatto, A., You, J.-M., & Wang, J. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta08358g · Cited by 317
A review on impedimetric biosensors
Bahadır, E. B., & Sezgintürk, M. K. (2014) · Artificial Cells Nanomedicine and Biotechnology · doi:10.3109/21691401.2014.942456 · Cited by 308
Amperometric biosensors for clinical and therapeutic drug monitoring: a review
Wang, J. (1999) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/s0731-7085(98)00056-9 · Cited by 294
A single-chamber microbial fuel cell as a biosensor for wastewaters
Lorenzo, M. D., Curtis, T. P., Head, I. M., & Scott, K. (2009) · Water Research · doi:10.1016/j.watres.2009.01.005 · Cited by 286
Zhou, M., & Dong, S. (2011) · Accounts of Chemical Research · doi:10.1021/ar200096g · Cited by 284
Enzymatic biofuel cells designed for direct power generation from biofluids in living organisms
Miyake, T., Haneda, K., Nagai, N., Yatagawa, Y., Onami, H., Yoshino, S., Abe, T., & Nishizawa, M. (2011) · Energy & Environmental Science · doi:10.1039/c1ee02200h · Cited by 247
A small-scale air-cathode microbial fuel cell for on-line monitoring of water quality
Lorenzo, M. D., Thomson, A. R., Schneider, K. J., Cameron, P. J., & Ieropoulos, I. A. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.06.050 · Cited by 244
Biofuel Cells: Enhanced Enzymatic Bioelectrocatalysis
Meredith, M. T., & Minteer, S. D. (2012) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062011-143049 · Cited by 214
Self-citationA novel biomonitoring system using microbial fuel cells
Kim, M., Hyun, M. S., Gadd, G. M., & Kim, H. J. (2007) · Journal of Environmental Monitoring · doi:10.1039/b713114c · Cited by 213
Silicon-based microfabricated microbial fuel cell toxicity sensor
Dávila, D., Esquivel, J. P., Sabaté, N., & Mas, J. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.10.025 · Cited by 195
Microneedle-based self-powered glucose sensor
Valdés‐Ramírez, G., Li, Y.-C., Kim, J., Jia, W., Bandodkar, A. J., Nuñez‐Flores, R., Miller, P. R., Wu, S., Narayan, R. J., Windmiller, J. R., et al. (2014) · Electrochemistry Communications · doi:10.1016/j.elecom.2014.07.014 · Cited by 189
A screen-printed paper microbial fuel cell biosensor for detection of toxic compounds in water
Chouler, J., Cruz-Izquierdo, Á., Rengaraj, S., Scott, J. L., & Lorenzo, M. D. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.11.018 · Cited by 178
Cholesterol Self-Powered Biosensor
Sekretareva, A., Beni, V., Eriksson, M., Karyakin, A. A., Turner, A. P. F., & Vagin, M. Y. (2014) · Analytical Chemistry · doi:10.1021/ac501699p · Cited by 176
Biofuel Cell Controlled by Enzyme Logic Systems
Amir, L., Tam, T. K., Pita, M., Meijler, M. M., Alfonta, L., & Katz, E. (2008) · Journal of the American Chemical Society · doi:10.1021/ja8076704 · Cited by 173
Microbial fuel cell biosensor for in situ assessment of microbial activity
Tront, J. M., Fortner, J. D., Plötze, M. L., Hughes, J. B., & Puzrin, A. M. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.06.006 · Cited by 171
Kaur, A., Kim, J. R., Michie, I. S., Dinsdale, R. M., Guwy, A. J., & Premier, G. C. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.02.033 · Cited by 165
Hickey, D. P., Reid, R. C., Milton, R. D., & Minteer, S. D. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.09.013 · Cited by 160
Self-citationA batch-mode cube microbial fuel cell based “shock” biosensor for wastewater quality monitoring
Liu, B., Lei, Y., & Li, B. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.06.051 · Cited by 153
Yu, D., Bai, L., Zhai, J., Wang, Y., & Dong, S. (2017) · Talanta · doi:10.1016/j.talanta.2017.03.048 · Cited by 153
Zhou, M., Zhou, N., Kuralay, F., Windmiller, J. R., Parkhomovsky, S., Valdés‐Ramírez, G., Katz, E., & Wang, J. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201107068 · Cited by 147
Yang, Y. F., Zhang, H., Chen, J., Lee, S., Hou, T., & Wang, Z. L. (2013) · Energy & Environmental Science · doi:10.1039/c3ee40764k · Cited by 141
Zhou, M., Du, Y., Chen, C., Li, B., Wen, D., Dong, S., & Wang, E. (2010) · Journal of the American Chemical Society · doi:10.1021/ja910634e · Cited by 134
Effect of shear rate on the response of microbial fuel cell toxicity sensor to Cu(II)
Shen, Y., Wang, M., Chang, I. S., & Ng, H. Y. (2013) · Bioresource Technology · doi:10.1016/j.biortech.2013.02.069 · Cited by 132
Bacteria-based AND logic gate: a decision-making and self-powered biosensor
Li, Z., Rosenbaum, M. A., Venkataraman, A., Tam, T. K., Katz, E., & Angenent, L. T. (2011) · Chemical Communications · doi:10.1039/c0cc05037g · Cited by 129
Self-Powered Sensor for Trace Hg2+ Detection
Wen, D., Deng, L., Guo, S., & Dong, S. (2011) · Analytical Chemistry · doi:10.1021/ac2001884 · Cited by 127
Current Trends in Nanomaterial-Based Amperometric Biosensors
Hayat, A., Catanante, G., & Marty, J. (2014) · Sensors · doi:10.3390/s141223439 · Cited by 125
Self-Powered Wireless Carbohydrate/Oxygen Sensitive Biodevice Based on Radio Signal Transmission
Falk, M., Alcalde, M., Bartlett, P. N., Lacey, A. L. D., Gorton, L. G. O., Gutiérrez‐Sánchez, C., Haddad, R., Kilburn, J., Leech, D., Ludwig, R., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0109104 · Cited by 119
FePO4 based single chamber air-cathode microbial fuel cell for online monitoring levofloxacin
Zeng, L., Li, X., Shi, Y., Yefei, Q., Huang, D., Tadé, M. O., Wang, S., & Liu, S. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.12.021 · Cited by 119
Chen, C.-H., Lee, P.-W., Tsao, Y.-H., & Lin, Z. (2017) · Nano Energy · doi:10.1016/j.nanoen.2017.10.064 · Cited by 117
Self-powered biosensor for ascorbic acid with a Prussian blue electrochromic display
Zloczewska, A., Celebańska, A., Szot, K., Tomaszewska, D., Opałło, M., & Jönsson‐Niedziółka, M. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.033 · Cited by 115
Enantioselective electrochemical sensors and biosensors: A mini-review
Trojanowicz, M. (2013) · Electrochemistry Communications · doi:10.1016/j.elecom.2013.10.034 · Cited by 114
A 3D paper-based enzymatic fuel cell for self-powered, low-cost glucose monitoring
Fischer, C., Fraiwan, A., & Choi, S. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.12.020 · Cited by 114
Moreira, F. T. C., Sales, M. G. F., & Lorenzo, M. D. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.08.104 · Cited by 112
Arechederra, R. L., Waheed, A., Sly, W. S., Supuran, C. T., & Minteer, S. D. (2012) · Bioorganic & Medicinal Chemistry · doi:10.1016/j.bmc.2012.06.053 · Cited by 110
Self-citationIntegrated Self-Powered Microchip Biosensor for Endogenous Biological Cyanide
Liu, D., Chen, C., Zhou, M., Guo, S., Wang, E., & Dong, S. (2010) · Analytical Chemistry · doi:10.1021/ac100274s · Cited by 102
Self‐Charging Electrochemical Biocapacitor
Pankratov, D., Blum, Z., Suyatin, D. B., Popov, V. O., & Shleev, S. (2013) · ChemElectroChem · doi:10.1002/celc.201300142 · Cited by 98
Exploring the use of cost-effective membrane materials for Microbial Fuel Cell based sensors
Chouler, J., Bentley, I., Vaz, F., O’Fee, A., Cameron, P. J., & Lorenzo, M. D. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.01.195 · Cited by 95
Ayyaru, S., & Dharmalingam, S. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.01.059 · Cited by 91
Wearable Sensor System Powered by a Biofuel Cell for Detection of Lactate Levels in Sweat
Garcia, S. O., Ulyanova, Y., Figueroa-Teran, R., Bhatt, K. H., Singhal, S., & Atanassov, P. B. (2016) · ECS Journal of Solid State Science and Technology · doi:10.1149/2.0131608jss · Cited by 88
A Self-Powered Acetaldehyde Sensor Based on Biofuel Cell
Zhang, L., Zhou, M., & Dong, S. (2012) · Analytical Chemistry · doi:10.1021/ac302414a · Cited by 87
Xu, Z., Liu, B., Dong, Q., Lei, Y., Li, Y., Ren, J., McCutcheon, J. R., & Li, B. (2015) · Bioresource Technology · doi:10.1016/j.biortech.2015.08.081 · Cited by 78
Biofuel Cell Based Self-Powered Sensing Platform for l -Cysteine Detection
Hou, C., Fan, S., Lang, Q., & Liu, A. (2015) · Analytical Chemistry · doi:10.1021/ac504694z · Cited by 78
BioCapacitor—A novel category of biosensor
Hanashi, T., Yamazaki, T., Tsugawa, W., Ferri, S. R., Nakayama, D., Tomiyama, M., Ikebukuro, K., & Sode, K. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.09.014 · Cited by 77
Sheikhyousefi, P. R., Esfahany, M. N., Colombo, A., Franzetti, A., Trasatti, S. P. M., & Cristiani, P. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.10.057 · Cited by 74
Bioelectrochemical Systems as a Multipurpose Biosensing Tool: Present Perspective and Future Outlook
Grattieri, M., Hasan, K., & Minteer, S. D. (2016) · ChemElectroChem · doi:10.1002/celc.201600507 · Cited by 72
Self-citationTailoring Biointerfaces for Electrocatalysis
Milton, R. D., Wang, T., Knoche, K. L., & Minteer, S. D. (2016) · Langmuir · doi:10.1021/acs.langmuir.5b04742 · Cited by 70
Self-citationXu, Z., Liu, Y., Williams, I., Li, Y., Qian, F., Zhang, H., Cai, D., Wang, L., & Li, B. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.05.018 · Cited by 70
Pankratov, D., Conzuelo, F., Pinyou, P., Alsaoub, S., Schuhmann, W. W., & Shleev, S. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201607144 · Cited by 69
Nitroaromatic Actuation of Mitochondrial Bioelectrocatalysis for Self-Powered Explosive Sensors
Germain, M. N., Arechederra, R. L., & Minteer, S. D. (2008) · Journal of the American Chemical Society · doi:10.1021/ja807250b · Cited by 67
Self-citationTam, T. K., Strack, G., Pita, M., & Katz, E. (2009) · Journal of the American Chemical Society · doi:10.1021/ja9048459 · Cited by 67
A cathode-shared microbial fuel cell sensor array for water alert system
Jiang, Y. G., Liang, P., Liu, P., Yan, X., Bian, Y., & Huang, X. (2016) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2016.12.050 · Cited by 67
Microbial fuel-cell-based toxicity sensor for fast monitoring of acidic toxicity
Shen, Y. J., Lefebvre, O., Tan, Z., & Ng, H. Y. (2012) · Water Science & Technology · doi:10.2166/wst.2012.957 · Cited by 66
Knoche, K. L., Hickey, D. P., Milton, R. D., Curchoe, C. L., & Minteer, S. D. (2016) · ACS Energy Letters · doi:10.1021/acsenergylett.6b00225 · Cited by 65
Self-citationInhibition and Activation of Glucose Oxidase Bioanodes for Use in a Self-Powered EDTA Sensor
Meredith, M. T., & Minteer, S. D. (2011) · Analytical Chemistry · doi:10.1021/ac2011087 · Cited by 64
Self-citationMiniature Amperometric Self-Powered Continuous Glucose Sensor with Linear Response
Liu, Z., Cho, B., Ouyang, T., & Feldman, B. (2012) · Analytical Chemistry · doi:10.1021/ac300217p · Cited by 64
Wang, T., Milton, R. D., Abdellaoui, S., Hickey, D. P., & Minteer, S. D. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04651 · Cited by 63
Self-citationSelf-Powered Sensor for Naked-Eye Detection of Serum Trypsin
Zaccheo, B. A., & Crooks, R. M. (2011) · Analytical Chemistry · doi:10.1021/ac103115z · Cited by 62
Schievano, A., Colombo, A., Cossettini, A., Goglio, A., D’Ardes, V., Trasatti, S. P. M., & Cristiani, P. (2017) · Waste Management · doi:10.1016/j.wasman.2017.06.012 · Cited by 62
Cheng, J., Han, Y., Deng, L., & Guo, S. (2014) · Analytical Chemistry · doi:10.1021/ac503277w · Cited by 61
BioRadioTransmitter: A Self-Powered Wireless Glucose-Sensing System
Hanashi, T., Yamazaki, T., Tsugawa, W., Ikebukuro, K., & Sode, K. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500502 · Cited by 60
Cheng, H., Yu, P., Lu, X., Lin, Y., Ohsaka, T., & Mao, L. (2012) · The Analyst · doi:10.1039/c2an36385b · Cited by 59
Impact of tobramycin on the performance of microbial fuel cell
Wu, W., Lesnik, K. L., Xu, S., Wang, L., & Liu, H. (2014) · Microbial Cell Factories · doi:10.1186/s12934-014-0091-6 · Cited by 58
A Self‐Powered Ethanol Biosensor
Ruff, A., Pinyou, P., Nolten, M., Conzuelo, F., & Schuhmann, W. W. (2017) · ChemElectroChem · doi:10.1002/celc.201600864 · Cited by 56
Wang, Y., Ge, L., Ma, C., Kong, Q., Yan, M., Ge, S., & Yu, J. (2014) · Chemistry - A European Journal · doi:10.1002/chem.201403271 · Cited by 52
Self-powered herbicide biosensor utilizing thylakoid membranes
Rasmussen, M., & Minteer, S. D. (2013) · Analytical Methods · doi:10.1039/c3ay26488b · Cited by 50
Self-citationA Paper‐based Mitochondrial Electrochemical Biosensor for Pesticide Detection
Wang, T., Reid, R. C., & Minteer, S. D. (2015) · Electroanalysis · doi:10.1002/elan.201500487 · Cited by 50
Self-citationDNAzyme logic-controlled biofuel cells for self-powered biosensors
Zhou, M., Kuralay, F., Windmiller, J. R., & Wang, J. (2012) · Chemical Communications · doi:10.1039/c2cc30464c · Cited by 49
Yang, G., Sun, Y., Kong, X., Zhen, F., Li, Y., Li, D., Lei, T., Yuan, Z., & Chen, G. (2013) · Water Science & Technology · doi:10.2166/wst.2013.415 · Cited by 48
Noiseless Performance of Prussian Blue Based (Bio)sensors through Power Generation
Komkova, M. A., Karyakina, E. E., & Karyakin, A. A. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01142 · Cited by 46
Gai, P., Song, R., Cheng, Z., Ji, Y., Wang, W., Zhang, J., & Zhu, J. (2015) · Chemical Communications · doi:10.1039/c5cc07520c · Cited by 42
Alsaoub, S., Ruff, A., Conzuelo, F., Ventosa, E., Ludwig, R., Shleev, S., & Schuhmann, W. W. (2017) · ChemPlusChem · doi:10.1002/cplu.201700114 · Cited by 42
A Self‐Powered and Reusable Biocomputing Security Keypad Lock System Based on Biofuel Cells
Zhou, M., Zheng, X., Wang, J., & Dong, S. (2010) · Chemistry - A European Journal · doi:10.1002/chem.201000619 · Cited by 41
Zhang, T., Zhao, H., Ayue, L. E. I., & Quan, X. (2014) · Electrochemistry · doi:10.5796/electrochemistry.82.94 · Cited by 40
MacVittie, K., & Katz, E. (2014) · Chemical Communications · doi:10.1039/c4cc01540a · Cited by 39
Enhancement of the sensitivity of a microbial fuel cell sensor by transient-state operation
Jiang, Y. G., Liang, P., Liu, P., Miao, B., Bian, Y., Zhang, H., & Huang, X. (2017) · Environmental Science Water Research & Technology · doi:10.1039/c6ew00346j · Cited by 38
Conzuelo, F., Vivekananthan, J., Pöller, S., Pingarrón, J. M., & Schuhmann, W. W. (2014) · ChemElectroChem · doi:10.1002/celc.201402098 · Cited by 37
Zhou, M., Chen, C., Du, Y., Li, B., Wen, D., Dong, S., & Wang, E. (2010) · Lab on a Chip · doi:10.1039/c0lc00009d · Cited by 37
Self-Powered Electrochemical Lactate Biosensing
Baingane, A., & Slaughter, G. E. (2017) · Energies · doi:10.3390/en10101582 · Cited by 33
Nanobioelectrocatalysis and Its Applications in Biosensors, Biofuel Cells and Bioprocessing
Minteer, S. D. (2012) · Topics in Catalysis · doi:10.1007/s11244-012-9898-8 · Cited by 27
Self-citationBoolean logic gates based on oxygen-controlled biofuel cell in “one pot”
Zhou, M., Wang, F., & Dong, S. (2011) · Electrochimica Acta · doi:10.1016/j.electacta.2011.01.113 · Cited by 27
Han, Y., Chabu, J. M., Hu, S., Deng, L., Liu, Y., & Guo, S. (2015) · Chemistry - A European Journal · doi:10.1002/chem.201502062 · Cited by 26
Nanomaterials for Energy Storage Applications
Raj, R., Verma, R., & Singh, J. (2021) · Clean Energy Production Technologies · doi:10.1007/978-981-16-1888-8_7 · Cited by 18
Electrically wired mitochondrial electrodes for measuring mitochondrial function for drug screening
Arechederra, R. L., Waheed, A., Sly, W. S., & Minteer, S. D. (2011) · The Analyst · doi:10.1039/c1an15370f · Cited by 10
Self-citation
Research works printed but not linked: 1
- 10.1016/j.biortech.2015.08.081 · DOI
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 915
Functional Fibers and Fabrics for Soft Robotics, Wearables, and Human–Robot Interface
Xiong, J., Chen, J., & Lee, P. S. (2020) · Advanced Materials · doi:10.1002/adma.202002640 · Cited by 653
Tackling the Challenges of Enzymatic (Bio)Fuel Cells
Xiao, X., Xia, H.-Q., Wu, R., Bai, L., Yan, L., Magner, E., Cosnier, S., Lojou, É., Zhu, Z., & Liu, A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00115 · Cited by 520
Flexible Hybrid Sensors for Health Monitoring: Materials and Mechanisms to Render Wearability
Gao, Y., Yu, L., Yeo, J. C., & Lim, C. T. (2019) · Advanced Materials · doi:10.1002/adma.201902133 · Cited by 515
Metadata
- Authors
- Grattieri, M., & Minteer, S. D.
- Affiliations
- University of Utah (US)
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-12-05
- Volume
- 3
- Issue
- 1
- Pages
- 44-53
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W2770161173
- Cited by
- 312
- References
- 92
- Citations by year
- 2026: 20 · 2025: 34 · 2024: 35 · 2023: 29 · 2022: 38 · 2021: 44 · 2020: 49 · 2019: 37 · 2018: 23 · 2017: 2
- FWCI
- 1.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- ACS Sensors (publishedVersion)
- PubMed (publishedVersion)
- CINECA IRIS Institutional Research Information System (University of Bari Aldo Moro) (submittedVersion)
- Funders
- National Institute of Food and Agriculture
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Physical Sciences › Environmental Science › Environmental Engineering › Microbial Fuel Cells and Bioremediation
- Keywords
- self-powered biosensor, enzymatic biofuel cells, microbial fuel cells, bioelectrocatalysis, Boolean logic gates
- MeSH terms
- Bioelectric Energy Sources, Enzymes, Immobilized, Logic, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review