Cited by 312Electrochemical sensors and biosensorsAdvanced biosensing and bioanalysis techniquesMicrobial Fuel Cells and Bioremediation

The DOI matches its Crossref record; 92 of the 92 references it cites were found in a registry or an index.

Self-Powered Biosensors

Abstract

Self-powered electrochemical biosensors utilize biofuel cells as a simultaneous power source and biosensor, which simplifies the biosensor system, because it no longer requires a potentiostat, power for the potentiostat, and/or power for the signaling device. This review article is focused on detailing the advances in the field of self-powered biosensors and discussing their advantages and limitations compared to other types of electrochemical biosensors. The review will discuss self-powered biosensors formed from enzymatic biofuel cells, organelle-based biofuel cells, and microbial fuel cells. It also discusses the different mechanisms of sensing, including utilizing the analyte being the substrate/fuel for the biocatalyst, the analyte binding the biocatalyst to the electrode surface, the analyte being an inhibitor of the biocatalyst, the analyte resulting in the blocking of the bioelectrocatalytic response, the analyte reactivating the biocatalyst, Boolean logic gates, and combining affinity-based biorecognition elements with bioelectrocatalytic power generation. The final section of this review details areas of future investigation that are needed in the field, as well as problems that still need to be addressed by the field.

Overview

Integrity signals

Registry

Crossref · 10.1021/acssensors.7b00818

Cites

92 of 92 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 1

  1. 10.1016/j.biortech.2015.08.081 · DOI

Cited by

Sorted by citations

See all 312

Metadata

Authors
Grattieri, M., & Minteer, S. D.
Affiliations
University of Utah (US)
Venue
ACS Sensors
Published
2017-12-05
Volume
3
Issue
1
Pages
44-53
ISSN
2379-3694 (ISSN-L)
OpenAlex
W2770161173
Cited by
312
References
92
Citations by year
2026: 20 · 2025: 34 · 2024: 35 · 2023: 29 · 2022: 38 · 2021: 44 · 2020: 49 · 2019: 37 · 2018: 23 · 2017: 2
FWCI
1.39
Type
journal article
Language
en
Open access
closed
Locations
  • ACS Sensors (publishedVersion)
  • PubMed (publishedVersion)
  • CINECA IRIS Institutional Research Information System (University of Bari Aldo Moro) (submittedVersion)
Funders
National Institute of Food and Agriculture
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
  • Physical Sciences › Environmental Science › Environmental Engineering › Microbial Fuel Cells and Bioremediation
Keywords
self-powered biosensor, enzymatic biofuel cells, microbial fuel cells, bioelectrocatalysis, Boolean logic gates
MeSH terms
Bioelectric Energy Sources, Enzymes, Immobilized, Logic, Biosensing Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review