The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Photoactivated Mixed In-Plane and Edge-Enriched p-Type MoS2 Flake-Based NO2 Sensor Working at Room Temperature
Abstract
Toxic gases are produced during the burning of fossil fuels. Room temperature (RT) fast detection of toxic gases is still challenging. Recently, MoS 2 transition metal dichalcogenides have sparked great attention in the research community due to their performance in gas sensing applications. However, MoS 2 based gas sensors still suffer from long response and recovery times, especially at RT. Considering this challenge, here, we report photoactivated highly reversible and fast detection of NO 2 sensors at room temperature (RT) by using mixed in-plane and edge-enriched p-MoS 2 flakes (mixed MoS 2 ). The sensor showed fast response with good sensitivity of ∼10.36% for 10 ppm of NO 2 at RT without complete recovery. However, complete recovery was obtained with better sensor performance under UV light illumination at RT. The UV assisted NO 2 sensing showed improved performance in terms of fast response and recovery kinetics with enhanced sensitivity to 10 ppm NO 2 concentration. The sensor performance is also investigated under thermal energy, and a better sensor performance with reduced sensitivity and high selectivity toward NO 2 was observed. A detailed gas sensing mechanism based on the density functional theory (DFT) calculations for favorable NO 2 adsorption sites on in-plane and edge-enriched MoS 2 flakes is proposed. This study revealed the role of favorable adsorption sites in MoS 2 flakes for the enhanced interaction of target gases and developed a highly sensitive, reversible, and fast gas sensor for next-generation toxic gases at room temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Identification of Active Edge Sites for Electrochemical H 2 Evolution from MoS 2 Nanocatalysts
Jaramillo, T. F., Jørgensen, K. P., Bonde, J., Nielsen, J. H., Horch, S., & Chorkendorff, I. (2007) · Science · doi:10.1126/science.1141483 · Cited by 6,100
High Surface Area MoS 2 /Graphene Hybrid Aerogel for Ultrasensitive NO 2 Detection
Long, H., Harley‐Trochimczyk, A., Pham, T., Tang, Z., Shi, T., Zettl, A., Carraro, C., Worsley, M. A., & Maboudian, R. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201601562 · Cited by 479
Cited by
Recent Advances in Electrochemical Sensors for Detecting Toxic Gases: NO2, SO2 and H2S
Khan, M. A. H., Rao, M. V., & Li, Q. (2019) · Sensors · doi:10.3390/s19040905 · Cited by 417
Optimized Metal Chalcogenides for Boosting Water Splitting
Yin, J., Jin, J., Lin, H., Yin, Z., Li, J., Lu, M., Guo, L., Xi, P., Tang, Y., & Yan, C. (2020) · Advanced Science · doi:10.1002/advs.201903070 · Cited by 292
MoS2‐Based Nanomaterials for Room‐Temperature Gas Sensors
Kumar, R., Zheng, W., Liu, X., Zhang, J., & Kumar, M. (2020) · Advanced Materials Technologies · doi:10.1002/admt.201901062 · Cited by 287
Self-citationRecent Advances in Emerging 2D Material‐Based Gas Sensors: Potential in Disease Diagnosis
Zhang, L., Khan, K., Zou, J., Zhang, H., & Li, Y. (2019) · Advanced Materials Interfaces · doi:10.1002/admi.201901329 · Cited by 281
Metadata
- Authors
- Agrawal, A. V., Kumar, R., Venkatesan, S., Zakhidov, A., Yang, G., Bao, J., Kumar, M., & Kumar, M.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-04-17
- Volume
- 3
- Issue
- 5
- Pages
- 998-1004
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W2801189401
- Cited by
- 214
- References
- 2
- FWCI
- 9.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Photoactivated Mixed In-Plane and Edge-Enriched p-Type MoS2 Flake-Based NO2 Sensor Working at Room Temperature. https://app.cochat.ai/papers/10.1021/acssensors.8b00146
- The paper
- Agrawal, A. V., Kumar, R., Venkatesan, S., Zakhidov, A., Yang, G., Bao, J., Kumar, M., & Kumar, M. (2018). Photoactivated Mixed In-Plane and Edge-Enriched p-Type MoS2 Flake-Based NO2 Sensor Working at Room Temperature. ACS Sensors. https://doi.org/10.1021/acssensors.8b00146
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.