The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Ultrasensitive and Fully Reversible NO2 Gas Sensing Based on p-Type MoTe2 under Ultraviolet Illumination
Abstract
The unique properties of two-dimensional (2D) materials make them promising candidates for chemical and biological sensing applications. However, most 2D material sensors suffer from extremely long recovery time due to the slow molecular desorption at room temperature. Here, we report an ultrasensitive p-type molybdenum ditelluride (MoTe 2 ) gas sensor for NO 2 detection with greatly enhanced sensitivity and recovery rate under ultraviolet (UV) illumination. Specifically, the sensitivity of the sensor to NO 2 is dramatically enhanced by 1 order of magnitude under 254 nm UV illumination as compared to that in the dark condition, leading to a remarkable low detection limit of 252 ppt. More importantly, the p-type MoTe 2 sensor can achieve full recovery after each sensing cycle well within 160 s at room temperature. Finally, the p-type MoTe 2 sensor also exhibits excellent sensing performance to NO 2 in ambient air and negligible response to H 2 O, indicating its great potential in practical applications, such as breath analysis and ambient NO 2 detection. Such impressive features originate from the activated interface interaction between the gas molecules and p-type MoTe 2 surface under UV illumination. This work provides a promising and easily applicable strategy to improve the performance of the gas sensors based on 2D materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Outdoor air pollution and asthma.
Guarnieri, M., & Balmes, J. R. (2014) · The Lancet · doi:10.1016/s0140-6736(14)60617-6 · Cited by 1,889
Single-layer MoSe2 based NH3 gas sensor
Late, D. J., Doneux, T., & Bougouma, M. (2014) · Applied Physics Letters · doi:10.1063/1.4903358 · Cited by 407
Cited by
Room-Temperature Gas Sensors Under Photoactivation: From Metal Oxides to 2D Materials
Kumar, R., Liu, X., Zhang, J., & Kumar, M. (2020) · Nano-Micro Letters · doi:10.1007/s40820-020-00503-4 · Cited by 413
Emerging van der Waals junctions based on TMDs materials for advanced gas sensors
Zheng, W., Liu, X., Xie, J., Lu, G., & Zhang, J. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214151 · Cited by 254
Li, T., Yin, W., Gao, S., Sun, Y., Xu, P., Wu, S., Kong, H., Yang, G., & Wei, G. (2022) · Nanomaterials · doi:10.3390/nano12060982 · Cited by 222
Zeng, J., Xu, Y., Yu, J., Zhang, X., Zhang, X., Jin, H., Jin, Q., Shen, W., Zou, J., Deng, S., et al. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00981 · Cited by 42
Metadata
- Authors
- Wu, E., Xie, Y., Yuan, B., Zhang, H., Hu, X., Liu, J., & Zhang, D.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-08-14
- Volume
- 3
- Issue
- 9
- Pages
- 1719-1726
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W2885967548
- Cited by
- 209
- References
- 2
- FWCI
- 6.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.