In Vivo and In Vitro Monitoring of Amyloid Aggregation via BSA@FGQDs Multimodal Probe
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Early detection of peptide aggregate intermediates is quite challenging because of their variable and complex nature as well as due to lack of reliable sensors for diagnosis. Herein, we report the detection of monomers and oligomers using specified fluorescence and a magnetic resonance imaging (MRI) multimodal probe based on bovine-serum-albumin-capped fluorine functionalized graphene quantum dots (BSA@FGQDs). This probe enables in vitro fluorescence-based monitoring of human islet amyloid polypeptide (hIAPP), insulin, and amyloid β (1–42) (Aβ 42 ) monomers and oligomers during the fibrillogenesis dynamic. Up to 90% fluorescence quenching of BSA@FGQDs probe upon addition of amyloid monomers/oligomers was observed due to static quenching and nonradiative energy transfer. Moreover, the BSA@FGQDs probe shows 10 times higher signals in detecting amyloid intermediates and fibrils than that of conventional thioflavin dye. A negative Δ G ° value (−36.21 kJ/mol) indicates spontaneous interaction of probe with the peptide. These interactions are hydrogen bonding and hydrophobic as proved by thermodynamic parameters. Visual binding clues of BSA@FGQDs with different morphological states of amyloid protein was achieved through electron microscopy. Furthermore, intravenous and intracranial injection of BSA@FGQDs probe in Alzheimer model mice brain enabled in vivo detection of amyloid plaques in live mice brain by 19 F MRI through contrast enhancement. Our proposed probe not only effectively monitors in vitro fibrillation kinetics of number of amyloid proteins with higher sensitivity and specificity than thioflavin dye, but also, the presence of a 19 F center makes BSA@FGQDs an effective probe as a noninvasive and nonradiative in vivo detection probe for amyloid plaques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glowing Graphene Quantum Dots and Carbon Dots: Properties, Syntheses, and Biological Applications
Zheng, X. T., Ananthanarayanan, A., Luo, K. Q., & Chen, P. (2015) · Small · doi:10.1002/smll.201402648 · Cited by 2,190
Cited by
Interrogating Amyloid Aggregates using Fluorescent Probes
Aliyan, A., Cook, N. P., & Martí, A. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00404 · Cited by 290
Li, J., Zeng, H., Zeng, Z., Zeng, Y., & Xie, T. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.1c00875 · Cited by 257
Qasim, S., Zafar, A., Saif, M. S., Ali, Z., Nazar, M., Waqas, M., Haq, A. U., Tariq, T., Hassan, S. G., Iqbal, F., et al. (2020) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/j.jphotobiol.2020.111784 · Cited by 239
Self-citationQuantum Dots as A Theranostic Approach in Alzheimer’s Disease: A Systematic Review
Villalva, M. D., Agarwal, V., Ulanova, M., Sachdev, P. S., & Braidy, N. (2021) · Nanomedicine · doi:10.2217/nnm-2021-0104 · Cited by 53
Wang, W., Lin, X., Dong, X., & Sun, Y. (2022) · Acta Biomaterialia · doi:10.1016/j.actbio.2022.06.029 · Cited by 53
Metadata
- Authors
- Yousaf, M., Ahmad, M., Bhatti, I. A., Nasir, A., Hasan, M., Jian, X., Kalantar-Zadeh, K., & Mahmood, N.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-12-31
- Volume
- 4
- Issue
- 1
- Pages
- 200-210
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W2906920601
- Cited by
- 62
- References
- 1
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.