3D Hollow Quasi-Graphite Capsules/Polyaniline Hybrid with a High Performance for Room-Temperature Ammonia Gas Sensors
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Abstract Designing sensing materials with novel morphologies and compositions is eminently challenging to achieve high-performance gas sensor devices. Herein, an in situ oxidative polymerization approach is developed to construct three-dimensional (3D) hollow quasi-graphite capsules/polyaniline (GCs/PANI) hierarchical hybrids by decorating protonated PANI on the surface of GCs; as a result, an immensely active and sensitive material was developed for sensing ammonia gas at room temperature. Moreover, the GCs possessed a capsule-like hollow/open structure with partially graphitized walls, and PANI nanospheres were uniformly decorated on the GC surfaces. Furthermore, the inflexible and rigid 3D ordered chemistry of these materials provides the resulting hybrids with a large interfacial surface area, which not only allows for rapid adsorption and charge transfer but also provides the necessary structural stability. The 3D hollow GCs/PANI hybrids exhibit excellent performance; the GCs/PANI-3 hybrid is highly sensitive (with a response value of 1.30) toward 10 ppm NH3 gas and has short response and recovery times of 34 and 42 s, respectively. The GCs/PANI-3 hybrid also demonstrates a good selectivity, repeatability, and long-term stability, which are attributed to the substantial synergistic effect of the GCs and PANI. The design of such a unique 3D ordered framework provides a promising pathway to achieve room-temperature gas sensors for commercial applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A human pilot trial of ingestible electronic capsules capable of sensing different gases in the gut
Kalantar-Zadeh, K., Berean, K. J., Ha, N., Chrimes, A. F., Xu, K., Grando, D., Ou, J. Z., Pillai, N., Campbell, J. L., Brkljača, R., et al. (2018) · Nature Electronics · doi:10.1038/s41928-017-0004-x · Cited by 342
Cited by
Gas Sensors Based on Chemi-Resistive Hybrid Functional Nanomaterials
Jian, Y., Hu, W., Zhao, Z., Cheng, P., Haick, H., Yao, M., & Wu, W. (2020) · Nano-Micro Letters · doi:10.1007/s40820-020-0407-5 · Cited by 429
Wang, X., Zhang, D., Zhang, H., Gong, L., Yang, Y., Zhao, W., Yu, S., Yin, Y., & Sun, D. (2021) · Nano Energy · doi:10.1016/j.nanoen.2021.106242 · Cited by 268
Hydrogel-Based Gas Sensors for NO 2 and NH 3
Zhi, H., Gao, J., & Feng, L. (2020) · ACS Sensors · doi:10.1021/acssensors.9b02383 · Cited by 108
Zhu, H., Ji, H., Yuan, Z., Shen, Y., Gao, H., & Meng, F. (2023) · Journal of Materials Chemistry A · doi:10.1039/d3ta01426f · Cited by 59
Chen, T.-W., Ramachandran, R., Chen, S.-M., Anushya, G., & Ramachandran, K. (2020) · Sensors · doi:10.3390/s20236755 · Cited by 37
Metadata
- Authors
- Wang, H., Nie, S., Li, H., Ali, R., Fu, J., Xiong, H., Li, J., Wu, Z., Lau, W.-M., Mahmood, N., Jia, R., Liu, Y., & Jian, X.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-08-26
- Volume
- 4
- Issue
- 9
- Pages
- 2343-2350
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W2970340661
- Cited by
- 82
- References
- 1
- FWCI
- 3.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3D Hollow Quasi-Graphite Capsules/Polyaniline Hybrid with a High Performance for Room-Temperature Ammonia Gas Sensors. https://app.cochat.ai/papers/10.1021/acssensors.9b00882
- The paper
- Wang, H., Nie, S., Li, H., Ali, R., Fu, J., Xiong, H., Li, J., Wu, Z., Lau, W.-M., Mahmood, N., Jia, R., Liu, Y., & Jian, X. (2019). 3D Hollow Quasi-Graphite Capsules/Polyaniline Hybrid with a High Performance for Room-Temperature Ammonia Gas Sensors. ACS Sensors. https://doi.org/10.1021/acssensors.9b00882
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.