Cited by 108Gas Sensing Nanomaterials and SensorsHydrogels: synthesis, properties, applicationsPolydiacetylene-based materials and applications

Hydrogel-Based Gas Sensors for NO 2 and NH 3

Zhi, Hui, Gao, Jianmei, Feng, Liang·2020·ACS Sensors

Abstract

In this study, an innovative gas sensing mechanism, self-responsive sensing mechanism, has been detected in the supramolecular hydrogel-based sensors. The self-responsive ability of as-fabricated hydrogel-based sensors to the target gas (e.g., NO 2, NH 3, etc.) is determined by three synergetic supramolecular interactions, namely, hydrogen bonding, molecule crystallization, and electrostatic interactions existing in hydroxyls, poly(vinyl alcohol) (PVA) crystallization, and poly(ionic liquids) of the intrinsic hydrogel networks, respectively. On account of unique synergetic supramolecular interactions, the sensors not only exhibit a rapid, reversible, and reproducible response but also show good tensile and compressive properties and excellent recovery property. The results demonstrate the potential of the self-responsive sensing mechanism as a pathway to realize a new generation of highly responsive hydrogel-based gas sensors.

Integrity signals

Registry

Crossref · 10.1021/acssensors.9b02383

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Recent studies have reported the use of hydrogels as the sensitive material for gas-sensing applications such as NO2, NH3, CO2, and O2.

    “Recent studies have reported the use of hydrogels as the sensitive material for gas-sensing applications, such as NO2, NH3, CO2, and O2”
  • Zhi et al. [68] prepared NH3 and NO2 hydrogel gas sensors based on PVA and CA double networks with a response of 31.60%, response/recovery times of 46/9 s for 40 ppm NH3, and low LODs of 140.85 ppb while being stretchable.

    “Zhi et al. [68] prepared NH3 and NO2 hydrogel gas sensors based on PVA and CA double networks with the response of 31.60%, response/recovery times of 46/9 s for 40 ppm NH3 and low LODs of 140.85 ppb while being stretchable.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Zhi, H., Gao, J., & Feng, L.
Affiliations
Dalian Institute of Chemical Physics (CN)
Corresponding author
Feng, Liang
Venue
ACS Sensors
Published
2020-02-21
Volume
5
Issue
3
Pages
772-780
ISSN
2379-3694 (ISSN-L)
OpenAlex
W3007740269
Cited by
108
References
1
Citations by year
2026: 13 · 2025: 27 · 2024: 24 · 2023: 12 · 2022: 13 · 2021: 16 · 2020: 3
FWCI
3.78
Type
journal article
Language
en
Open access
closed
Locations
  • ACS Sensors (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Dalian Institute of Chemical Physics (DICP ZZBS201802)
  • Chinese Academy of Sciences (KFJ-STS-ZDTP-083)
  • Dalian Distinguished Young Scholars (2018RJ02)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Medicine › Hydrogels: synthesis, properties, applications
  • Physical Sciences › Chemistry › Organic Chemistry › Polydiacetylene-based materials and applications
Keywords
NO2 gas sensing, NH3 sensing, supramolecular hydrogels, poly(ionic liquids), hydrogen bonding, electrostatic interactions, gas sensing mechanism
MeSH terms
Ammonia, Carrageenan, Crystallization, Hydrogen Bonding, Nitrogen Dioxide, Polyvinyl Alcohol, Tensile Strength, Water, Spectroscopy, Fourier Transform Infrared, Hydrogels, Static Electricity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review