Bioimaging of Glutathione with a Two-Photon Fluorescent Probe and Its Potential Application for Surgery Guide in Laryngeal Cancer
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
As the most abundant nonprotein biothiol in living cells, glutathione (GSH) prevents cellular components from oxidative damage and maintains the intracellular redox homeostasis. For further exploring whether GSH can be employed as a bioindicator to discriminate tumor lesion at a cellular level, the highly selective detection and accurate quantification of GSH under pathological conditions are critical. Herein, we design a coumarin derivative-based two-photon fluorescent probe Cou-Br for the detection of GSH in living cells, mice models, and clinical specimens. The prepared probe is capable of sensitively and selectively detecting GSH in complex biological systems. Cou-Br displays a good linear relationship in response to GSH and a low limit of detection. With the fluorescence signal positively associated with intracellular GSH levels, the probe enables real-time imaging of GSH in various cell lines. Under the condition of CS 2 stimulation, Cou-Br can rapidly respond to the fluctuation of intracellular GSH induced by oxidative damage. Furthermore, the in situ and in vivo bioimaging performances of Cou-Br are demonstrated. Typically, relying on the different cellular concentrations of GSH, the probe is successfully employed to identify the human laryngeal cancer lesion with outstanding capabilities of deep tissue imaging and tumor margin recognition. We assume that the abnormal expression level of GSH may be utilized as a potential bioindicator to discriminate tumor tissues from the surrounding disease-free tissues. To conclude, the proposed probe Cou-Br may potentially serve as a powerful chemical tool for the surgical navigation of cancer in clinic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xu, C., & Webb, W. W. (1996) · Journal of the Optical Society of America B · doi:10.1364/josab.13.000481 · Cited by 2,198
Recent progresses in small-molecule enzymatic fluorescent probes for cancer imaging
Liu, H.-W., Chen, L., Xu, C., Li, Z., Zhang, H., Zhang, X.-B., & Tan, W. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00862g · Cited by 948
Fluorescent chemical probes for accurate tumor diagnosis and targeting therapy
Gao, M., Yu, F., Lv, C., Choo, J., & Chen, L. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00908e · Cited by 827
Self-citation
Cited by
Wang, C., Lin, H., Ge, X., Mu, J., Su, L., Zhang, X., Niu, M., Yang, H., & Song, J. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009942 · Cited by 89
Analysis of extracellular vesicles as emerging theranostic nanoplatforms
Xing, Y., Cheng, Z., Wang, R., Lv, C., James, T. D., & Yu, F. (2020) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213506 · Cited by 67
Self-citationZhao, Y., Li, L., Ye, Q., Gong, Y., Yang, R., & Liu, H. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.3c02664 · Cited by 47
Metadata
- Authors
- Zou, Y., Li, M., Xing, Y., Duan, T., Zhou, X., & Yu, F.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-12-09
- Volume
- 5
- Issue
- 1
- Pages
- 242-249
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W2995247277
- Cited by
- 109
- References
- 3
- FWCI
- 4.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.