MoS2/MoO3 Nanocomposite for Selective NH3 Detection in a Humid Environment
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Designing a material with novel sensing properties under extreme working conditions has remained a challenging task. Here, we report a facile two-step approach to develop a MoS 2 /MoO 3 composite with enhanced surface properties. When used as a gas sensor at 25 °C, it displayed superior sensing properties, selectivity, and a stable response toward ammonia against various reducing and oxidizing gases under highly humid conditions (relative humidity ≈ 95%). The composite exhibited a relative response of ≈55% (15% for 1 ppm) toward 50 ppm of NH 3 with smaller response τ res. and recovery τ rev. times of 45 and 53 s, respectively. It also displayed complete recovery without any external optical or thermal stimulus. The enhanced sensing properties of the composite are attributed to the synergistic effect arising from heterostructure formation between two base materials. The sensor displayed a decrease in resistance when exposed to NH 3, a reducing gas, thus indicating its n-type character, which was further confirmed by performing Mott–Schottky (MS) measurements on MoS 2 and the MoS 2 /MoO 3 composite, both displaying n-type behavior with increased electron densities of the composite. Further, to understand the adsorption process and the resulting sensing properties, density functional theory simulations were performed using a pristine and a defect-enriched MoS 2 /MoO 3 surface. Large negative adsorption energies (for NH 3 ) of −344 and −519 meV, respectively, reflect that the adsorption process is feasible, and mechanism change from physisorption to chemisorption is predicted. Bader scheme was employed to evaluate the charge transfer between the NH 3 molecule and the pristine (defect-enriched) MoS 2 /MoO 3 surface and gave an amount of 0.073 e (0.010 e ). Therefore, these results collectively justify the use of the MoS 2 /MoO 3 composite as a selective NH 3 sensor that can operate in humid air and environmental monitoring applications where such conditions exist.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Generalized Gradient Approximation Made Simple
Perdew, J. P., Burke, K., & Ernzerhof, M. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.3865 · Cited by 215,824
Semiempirical GGA‐type density functional constructed with a long‐range dispersion correction
Grimme, S. (2006) · Journal of Computational Chemistry · doi:10.1002/jcc.20495 · Cited by 31,038
A fast and robust algorithm for Bader decomposition of charge density
Henkelman, G., Arnaldsson, A., & Jónsson, H. (2006) · Computational Materials Science · doi:10.1016/j.commatsci.2005.04.010 · Cited by 10,723
"Special points for Brillouin-zone integrations"—a reply
Pack, J. D., & Monkhorst, H. J. (1977) · Physical Review B · doi:10.1103/physrevb.16.1748 · Cited by 3,307
Kibsgaard, J., Chen, Z., Reinecke, B. N., & Jaramillo, T. F. (2012) · Nature Materials · doi:10.1038/nmat3439 · Cited by 3,234
QuantumATK: an integrated platform of electronic and atomic-scale modelling tools
Smidstrup, S., Markussen, T., Vancraeyveld, P., Wellendorff, J., Schneider, J., Gunst, T., Verstichel, B., Stradi, D., Khomyakov, P. A., Vej-Hansen, U. G., et al. (2020) · Journal of Physics: Condensed Matter · doi:10.1088/1361-648x/ab4007 · Cited by 1,920
Ammonia sensors and their applications—a review
Timmer, B., Olthuis, W., & Berg, A. V. D. (2005) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2004.11.054 · Cited by 1,714
Carbon Nanotube Chemical Sensors
Schroeder, V., Savagatrup, S., He, M., Lin, S., & Swager, T. M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00340 · Cited by 1,131
Yang, S., Jiang, C., & Wei, S.-H. (2017) · Applied Physics Reviews · doi:10.1063/1.4983310 · Cited by 876
Two-Dimensional Transition Metal Dichalcogenides and Metal Oxide Hybrids for Gas Sensing
Lee, E., Yoon, Y. S., & Kim, D.-J. (2018) · ACS Sensors · doi:10.1021/acssensors.8b01077 · Cited by 620
Cited by
Gas sensing performance of 2D nanomaterials/metal oxide nanocomposites: a review
Bhati, V. S., Kumar, M., & Banerjee, R. (2021) · Journal of Materials Chemistry C · doi:10.1039/d1tc01857d · Cited by 256
Emerging van der Waals junctions based on TMDs materials for advanced gas sensors
Zheng, W., Liu, X., Xie, J., Lu, G., & Zhang, J. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214151 · Cited by 254
Recent Progress on Anti-Humidity Strategies of Chemiresistive Gas Sensors
Wang, Y., & Zhou, Y. (2022) · Materials · doi:10.3390/ma15248728 · Cited by 180
Tian, X., Yao, L., Cui, X., Zhao, R., Chen, T., Xiao, X., & Wang, Y. (2022) · Journal of Materials Chemistry A · doi:10.1039/d1ta10773a · Cited by 179
Metadata
- Authors
- Singh, S., Deb, J., Sarkar, U., & Sharma, S.
- Venue
- ACS Sustainable Chemistry & Engineering
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-05-18
- Volume
- 9
- Issue
- 21
- Pages
- 7328-7340
- ISSN
- 2168-0485 (ISSN-L)
- OpenAlex
- W3163050650
- Cited by
- 166
- References
- 46
- FWCI
- 8.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.