Stack Design and Operation for Scaling Up the Capacity of Flow-Electrode Capacitive Deionization Technology
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Flow electrodes have recently been studied for use in capacitive deionization applications because of their continuous and high desalting efficiency. The production capacity of desalinated water in the flow-electrode capacitive deionization (FCDI) system is limited compared to infinite ion capacity of the flow electrodes due to restrictions in the flow rate of the influent/effluent. Therefore, we designed and fabricated an FCDI stack with five unit cells in order to increase the production capacity of desalinated water. Through inlet pressure measurements of the flow electrodes in the FCDI stack, we confirmed that the flow electrodes were uniformly segmented from the manifold formed in the FCDI stack into the flow channels of each unit cell. We also confirmed that there was no pressure increase at the flow electrode in the flow channel caused by an increase in the number of unit cells in the FCDI stack. Also, the FCDI stack showed a similar desalting efficiency when compared to that of the FCDI unit cell. On the basis of the results, we verified that the FCDI stack can be successfully used to scale up the desalinated water production capacity of the FCDI system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Desalination via a New Membrane Capacitive Deionization Process Utilizing Flow-Electrodes
Jeon, S.-I., Park, H.-R., Yeo, J.-G., Yang, S., Cho, C. H., Han, M. H., & Kim, D. K. (2013) · Energy & Environmental Science · doi:10.1039/c3ee24443a · Cited by 727
Self-citation
Cited by
Electrochemical Methods for Water Purification, Ion Separations, and Energy Conversion
Alkhadra, M. A., Su, X., Suss, M. E., Tian, H., Guyes, E. N., Shocron, A. N., Conforti, K. M., de Souza, J. P., Kim, N., Tedesco, M., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00396 · Cited by 661
Various cell architectures of capacitive deionization: Recent advances and future trends
Tang, W., Liang, J., He, D., Gong, J., Tang, L., Liu, Z., Wang, D., & Zeng, G. (2019) · Water Research · doi:10.1016/j.watres.2018.11.064 · Cited by 461
Zhang, C., Ma, J., Wu, L., Sun, J., Wang, L., Li, T., & Waite, T. D. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.0c06552 · Cited by 323
Flow-electrode capacitive deionization: A review and new perspectives
Yang, F., He, Y., Rosentsvit, L., Suss, M. E., Zhang, X., Gao, T., & Liang, P. (2021) · Water Research · doi:10.1016/j.watres.2021.117222 · Cited by 233
Folaranmi, G., Bechelany, M., Sistat, P., Cretin, M., & Zaviska, F. (2020) · Membranes · doi:10.3390/membranes10050096 · Cited by 149
Choi, S., Chang, B., Kang, J. H., Diallo, M. S., & Choi, J. W. (2017) · Journal of Membrane Science · doi:10.1016/j.memsci.2017.07.043 · Cited by 60
Metadata
- Authors
- Yang, S., Jeon, S.-I., Kim, H., Choi, J., Yeo, J.-G., Park, H.-R., & Kim, D. K.
- Venue
- ACS Sustainable Chemistry & Engineering
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-07-08
- Volume
- 4
- Issue
- 8
- Pages
- 4174-4180
- ISSN
- 2168-0485 (ISSN-L)
- OpenAlex
- W2466416325
- Cited by
- 87
- References
- 1
- FWCI
- 3.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.