The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Ordered Array of Gold Semishells on TiO2 Spheres: An Ultrasensitive and Recyclable SERS Substrate
Abstract
Ordered array of Au semishells on TiO(2) spheres with controlled size are prepared by combining the nanosphere self-assembly and atomic layer deposition (ALD). This ordered 2-D structure with designed array of metal nanogaps can be used as an ultrasensitive surface-enhanced Raman scattering (SERS) substrate with high reproducibility and stability. More importantly, the SERS substrates are recyclable, as enabled by their self-cleaning function due to the TiO(2) photocatalytic degradation of the target molecules. The high SERS sensitivity and recyclability are demonstrated by the detection of Rhodamine 6G (R6G) and brilliant cresyl blue (BCB) molecules. As both the nanosphere lithography and ALD are scalable processes, such 2-D ordered substrates may find applications in chemical sensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, J., Li, Y., Zhang, X., & Yang, B. (2010) · Advanced Materials · doi:10.1002/adma.201000755 · Cited by 649
Cited by
Enhanced Raman Scattering with Dielectrics
Alessandri, I., & Lombardi, J. R. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00365 · Cited by 655
Kochuveedu, S. T., Jang, Y. H., & Kim, D. H. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60043b · Cited by 575
Prakash, J., Sun, S., Swart, H. C., & Gupta, R. K. (2018) · Applied Materials Today · doi:10.1016/j.apmt.2018.02.002 · Cited by 324
Metadata
- Authors
- Li, X., Hu, H., Li, D., Shen, Z., Xiong, Q., Li, S., & Fan, H. J.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-04-05
- Volume
- 4
- Issue
- 4
- Pages
- 2180-2185
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2170239655
- Cited by
- 202
- References
- 1
- FWCI
- 8.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.