The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Polyethylenimine-Impregnated Resin for High CO2 Adsorption: An Efficient Adsorbent for CO2 Capture from Simulated Flue Gas and Ambient Air
Abstract
Polyethylenimine (PEI)-impregnated resins with high CO2 adsorption capacity were successfully prepared in this study. The nonpolar resin HP20 was suitable for PEI loading to achieve high CO2 adsorption, and the optimal PEI loading was 50 wt %. On the basis of the pore-size distribution of the resin before and after PEI modification, it can be found that mesopores of <43 nm were mainly responsible for PEI loading and pores in the range of 43-68 nm were probably favorable for CO2 diffusion. The adsorbed amount of CO2 on HP20/PEI-50 decreased with increasing adsorption temperature because of the dominant role of exothermic reaction of CO2 adsorption. The adsorption of CO2 on the adsorbent was very fast, and sorption equilibrium was achieved within 6 min at 75 °C. HP20/PEI-50 almost kept a stable adsorption capacity for CO2 at concentrations of 15 vol % and 400 ppm in the consecutive adsorption-desorption cycles, and its adsorption capacity was 181 mg/g from pure CO2 and 99.3 mg/g from 400 ppm CO2 at 25 °C, higher than all PEI-modified materials reported. The high volume-based amount of CO2 adsorbed on HP20/PEI-50 (96.0 mg/cm(3) at 25 °C and 84.5 mg/cm(3) at 75 °C for pure CO2) is beneficial to reducing the required volume of the adsorption bed for CO2 capture. This spherical and stable HP20/PEI-50 adsorbent with high and fast CO2 adsorption exhibits a very promising application in CO2 capture from flue gas and ambient air.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Post-Combustion CO 2 Capture Using Solid Sorbents: A Review
Samanta, A., Zhao, A., Shimizu, G. K. H., Sarkar, P., & Gupta, R. (2012) · Industrial & Engineering Chemistry Research · doi:10.1021/ie200686q · Cited by 1,889
Cited by
Direct Capture of CO2 from Ambient Air
Sanz-Pérez, E. S., Murdock, C. R., Didas, S. A., & Jones, C. W. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00173 · Cited by 2,406
Recycling of carbon dioxide to methanol and derived products – closing the loop
Goeppert, A., Czaun, M., Jones, J.-P., Surya Prakash, G. K., & Olah, G. A. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00122b · Cited by 1,528
Sorbents for the Direct Capture of CO 2 from Ambient Air
Shi, X., Xiao, H., Azarabadi, H., Song, J., Wu, X., Chen, X., & Lackner, K. S. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201906756 · Cited by 679
CO2 capture adsorbents functionalized by amine – bearing polymers: A review
Varghese, A. M., & Karanikolos, G. N. (2020) · International Journal of Greenhouse Gas Control · doi:10.1016/j.ijggc.2020.103005 · Cited by 363
Direct Air Capture of CO2 Using Amine Functionalized MIL-101(Cr)
Darunte, L. A., Oetomo, A. D., Walton, K. S., Sholl, D. S., & Jones, C. W. (2016) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.6b01692 · Cited by 353
Metadata
- Authors
- Chen, Z., Deng, S., Wei, H., Wang, B., Huang, J., & Yu, G.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-07-16
- Volume
- 5
- Issue
- 15
- Pages
- 6937-6945
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W1977797406
- Cited by
- 263
- References
- 1
- FWCI
- 21.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polyethylenimine-Impregnated Resin for High CO2 Adsorption: An Efficient Adsorbent for CO2 Capture from Simulated Flue Gas and Ambient Air. https://app.cochat.ai/papers/10.1021/am400661b
- The paper
- Chen, Z., Deng, S., Wei, H., Wang, B., Huang, J., & Yu, G. (2013). Polyethylenimine-Impregnated Resin for High CO2 Adsorption: An Efficient Adsorbent for CO2 Capture from Simulated Flue Gas and Ambient Air. ACS Applied Materials & Interfaces. https://doi.org/10.1021/am400661b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.