Flexible Miniaturized Nickel Oxide Thermistor Arrays via Inkjet Printing Technology
The DOI matches its Crossref record.
Abstract
In this study, an inkjet printing process was developed to produce thermistor arrays for temperature sensing applications. First, a formulation process was carefully performed to generate a stable nanoparticle ink for nickel oxide, a material with a large temperature coefficient of resistance. The thermistor was then fabricated by printing a square NiO thin film in between two parallel silver conductive tracks on either glass plates or polyimide films. The printed thermistor, which has an adjustable dimension with a sub-millimeter scale, can operate over a wide range from room temperature to 200 °C with great sensitivity (B values ~4300 K) without hysteretic effects. When printed on polyimide films, the thermistors can also be bent or attached to curved surfaces to provide accurate and reliable temperature measurements. Moreover, the thermistor responds quickly to small temperature changes and provides an effective tool for transient temperature measurements. Finally, a thermistor array was fabricated to show the flexibility of this inkjet printing process and to demonstrate the applicability of the printed devices for temperature sensing applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Advanced Carbon for Flexible and Wearable Electronics
Wang, C., Xia, K., Wang, H., Liang, X., Yin, Z., & Zhang, Y. (2019) · Advanced Materials · doi:10.1002/adma.201801072 · Cited by 1,300
Inkjet printing wearable electronic devices
Gao, M., Li, L., & Song, Y. (2017) · Journal of Materials Chemistry C · doi:10.1039/c7tc00038c · Cited by 535
Graphene-based wearable piezoresistive physical sensors
Zheng, Q., Lee, J.-H., Shen, X., Chen, X., & Kim, J.-K. (2020) · Materials Today · doi:10.1016/j.mattod.2019.12.004 · Cited by 486
Sensitive Wearable Temperature Sensor with Seamless Monolithic Integration
Shin, J., Jeong, B., Kim, J., Nam, V. B., Yoon, Y., Jung, J., Hong, S., Lee, H., Eom, H., Yeo, J., et al. (2020) · Advanced Materials · doi:10.1002/adma.201905527 · Cited by 449
Metadata
- Authors
- Huang, C.-C., Kao, Z.-K., & Liao, Y.-C.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-12-10
- Volume
- 5
- Issue
- 24
- Pages
- 12954-12959
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2334543142
- Cited by
- 127
- References
- 0
- FWCI
- 2.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible Miniaturized Nickel Oxide Thermistor Arrays via Inkjet Printing Technology. https://app.cochat.ai/papers/10.1021/am404872j
- The paper
- Huang, C.-C., Kao, Z.-K., & Liao, Y.-C. (2013). Flexible Miniaturized Nickel Oxide Thermistor Arrays via Inkjet Printing Technology. ACS Applied Materials & Interfaces. https://doi.org/10.1021/am404872j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.