The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Sensitive Wearable Temperature Sensor with Seamless Monolithic Integration
Open accessAbstract
Accurate temperature field measurement provides critical information in many scientific problems. Herein, a new paradigm for highly sensitive, flexible, negative temperature coefficient (NTC) thermistor‐based artificial skin is reported, with the highest temperature sensing ability reported to date among previously reported NTC thermistors. This artificial skin is achieved through the development of a novel monolithic laser‐induced reductive sintering scheme and unique monolithic structures. The unique seamless monolithic structure simultaneously integrates two different components (a metal electrode and metal oxide sensing channel) from the same material at ambient pressure, which cannot be achieved by conventional heterogeneous integration through multiple, complex steps of photolithography or vacuum deposition. In addition to superior performance, electronic skin with high temperature sensitivity can be fabricated on heat‐sensitive polymer substrates due to the low‐temperature requirements of the process. As a proof of concept, temperature‐sensitive artificial skin is tested with conformally attachable physiological temperature sensor arrays in the measurement of the temperatures of exhaled breath for the early detection of pathogenic progression in the respiratory system. The proposed highly sensitive flexible temperature sensor and monolithic selective laser reductive sintering are expected to greatly contribute to the development of essential components in various emerging research fields, including soft robotics and healthcare systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The negative temperature coefficient (NTC) thermistor has a clear advantage over other temperature sensors in that it exhibits a much simpler structure while presenting equivalently high temperature sensitivity.[215]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [215]
Experimental — accuracy not yet measuredIn the citing paper
“It revealed a notable 27% rise in respiratory rate and a significant 65% reduction in temperature variation amplitude, indicating shallow breath, when confronted with low blood oxygen saturation levels.”
From Artificial intelligence enhanced sensors - enabling technologies to next-generation healthcare and biomedical platform (2023) · cites this paper as Shin et al. 2020
In the citing paper
“It has been demonstrated that it can capture small temperature variations associated with inhalation and exhalation. Besides, it was also able to accurately monitor changes in respiration patterns during intense physical activities.”
From Artificial intelligence enhanced sensors - enabling technologies to next-generation healthcare and biomedical platform (2023) · cites this paper as Shin et al. 2020
In the citing paper
“The nickel oxide (NiO) temperature sensor can be conformably attached to various curvatures on the facial surface, enabling continuous and accurate measurement of physiological temperature over long periods.”
From Artificial intelligence enhanced sensors - enabling technologies to next-generation healthcare and biomedical platform (2023) · cites this paper as Shin et al. 2020
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stretchable silicon nanoribbon electronics for skin prosthesis
Kim, J., Lee, M., Shim, H. J., Ghaffari, R., Cho, H. R., Son, D., Jung, Y. H., Soh, M., Choi, C., Jung, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms6747 · Cited by 1,435
Self-citationSomeya, T., Kato, Y., Sekitani, T., Iba, S., Noguchi, Y., Murase, Y., Kawaguchi, H., & Sakurai, T. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0502392102 · Cited by 1,389
Reproducible resistance switching in polycrystalline NiO films
Seo, S., Lee, M. J., Seo, D. H., Jeoung, E. J., Suh, D.-S., Joung, Y. S., Yoo, I. K., Hwang, I. R., Kim, S. H., Byun, I. S., et al. (2004) · Applied Physics Letters · doi:10.1063/1.1831560 · Cited by 933
Self-citationElectrical and Optical Properties of Narrow-Band Materials
Adler, D., & Feinleib, J. (1970) · Physical Review B · doi:10.1103/physrevb.2.3112 · Cited by 874
Trung, T. Q., Ramasundaram, S., Hwang, B., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504441 · Cited by 870
Negative Temperature Coefficient Resistance (NTCR) Ceramic Thermistors: An Industrial Perspective
Feteira, A. (2009) · Journal of the American Ceramic Society · doi:10.1111/j.1551-2916.2009.02990.x · Cited by 711
Mu, Y., Jia, D., He, Y., Miao, Y., & Wu, H.-L. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.11.042 · Cited by 466
Highly Stretchy Black Gold E‐Skin Nanopatches as Highly Sensitive Wearable Biomedical Sensors
Gong, S., Lai, D. T. H., Su, B., Si, K. J., Ma, Z., Yap, L. W., Guo, P., & Cheng, W. (2015) · Advanced Electronic Materials · doi:10.1002/aelm.201400063 · Cited by 461
A Flexible Bimodal Sensor Array for Simultaneous Sensing of Pressure and Temperature
Tien, N. T., Jeon, S., Kim, D., Trung, T. Q., Jang, M., Hwang, B., Byun, K., Bae, J., Lee, E., Tok, J. B. ‐., et al. (2014) · Advanced Materials · doi:10.1002/adma.201302869 · Cited by 438
Critical review of non-invasive respiratory monitoring in medical care
Folke, M., Cernerud, L., Ekström, M., & Hök, B. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02348078 · Cited by 430
Research works printed but not linked: 2
- Ryu J., 2009, J. Am. Chem. Soc., 92, 3084
- Mironova‐Ulmane N., 2011, Cent. Eur. J. Phys., 9, 1096
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Wen, F., Zhang, Z., He, T., & Lee, C. (2021) · Nature Communications · doi:10.1038/s41467-021-25637-w · Cited by 494
Wang, M., Luo, Y., Wang, T., Wan, C., Pan, L., Pan, S., He, K., Neo, A., & Chen, X. (2021) · Advanced Materials · doi:10.1002/adma.202003014 · Cited by 451
3D Printed Flexible Strain Sensors: From Printing to Devices and Signals
Liu, H., Zhang, H., Han, W., Lin, H., Li, R., Zhu, J., & Huang, W. (2021) · Advanced Materials · doi:10.1002/adma.202004782 · Cited by 441
Materials-Driven Soft Wearable Bioelectronics for Connected Healthcare
Gong, S., Lu, Y., Yin, J., Levin, A., & Cheng, W. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00502 · Cited by 411
Metadata
- Authors
- Shin, J., Jeong, B., Kim, J., Nam, V. B., Yoon, Y., Jung, J., Hong, S., Lee, H., Eom, H., Yeo, J., Choi, J., Lee, D., & Ko, S. H.
- Affiliations
- Seoul National University (KR)
- Gachon University (KR)
- Hanyang University (KR)
- Pusan National University (KR)
- Korea Institute of Industrial Technology (KR)
- Kyungpook National University (KR)
- Corresponding author
- Lee, Daeho
- Ko, Seung Hwan
- ORCID
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2019-11-07
- Volume
- 32
- Issue
- 2
- Pages
- e1905527-e1905527
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2989431324
- Semantic Scholar
- cacc34e6361bebd59ccdcb1210f450f17ed78755
- Cited by
- 449
- References
- 51
- Citations by year
- 2026: 35 · 2025: 96 · 2024: 93 · 2023: 71 · 2022: 67 · 2021: 62 · 2020: 24 · 2019: 1
- FWCI
- 13.55
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Advanced Materials (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Seoul National University Open Repository (Seoul National University) (submittedVersion)
- Funders
- National Research Foundation of Korea (2017R1A2B3005706, 2018R1D1A1B07042735)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Thermal Properties of Materials
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
- Keywords
- wearable temperature sensors, NTC thermistor, artificial skin, electronic skin, monolithic integration, respiratory disease detection, soft robotics
- MeSH terms
- Wearable Electronic Devices, Temperature, Skin, Artificial, Mechanical Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensitive Wearable Temperature Sensor with Seamless Monolithic Integration. https://app.cochat.ai/papers/10.1002/adma.201905527
- The paper
- Shin, J., Jeong, B., Kim, J., Nam, V. B., Yoon, Y., Jung, J., Hong, S., Lee, H., Eom, H., Yeo, J., Choi, J., Lee, D., & Ko, S. H. (2020). Sensitive Wearable Temperature Sensor with Seamless Monolithic Integration. Advanced Materials. https://doi.org/10.1002/adma.201905527
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.