The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Availability of the Basal Planes of Graphene Oxide Determines Whether It Is Antibacterial
Abstract
There are significant controversies on the antibacterial properties of graphene oxide (GO): GO was reported to be bactericidal in saline, whereas its activity in nutrient broth was controversial. To unveil the mechanisms underlying these contradictions, we performed antibacterial assays under comparable conditions. In saline, bare GO sheets were intrinsically bactericidal, yielding a bacterial survival percentage of <1% at 200 μg/mL. Supplementing saline with ≤10% Luria-Bertani (LB) broth, however, progressively deactivated its bactericidal activity depending on LB-supplementation ratio. Supplementation of 10% LB made GO completely inactive; instead, ∼100-fold bacterial growth was observed. Atomic force microscopy images showed that certain LB components were adsorbed on GO basal planes. Using bovine serum albumin and tryptophan as well-defined model adsorbates, we found that noncovalent adsorption on GO basal planes may account for the deactivation of GO's bactericidal activity. Moreover, this deactivation mechanism was shown to be extrapolatable to GO's cytotoxicity against mammalian cells. Taken together, our observations suggest that bare GO intrinsically kills both bacteria and mammalian cells and noncovalent adsorption on its basal planes may be a global deactivation mechanism for GO's cytotoxicity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Using Graphene Oxide High Near‐Infrared Absorbance for Photothermal Treatment of Alzheimer's Disease
Li, M., Yang, X., Ren, J., Qu, K., & Qu, X. (2012) · Advanced Materials · doi:10.1002/adma.201104864 · Cited by 535
Cited by
Mechanisms of the Antimicrobial Activities of Graphene Materials
Zou, X., Zhang, L., Wang, Z., & Luo, Y. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.5b11411 · Cited by 934
Mohammed, H., Kumar, A., Bekyarova, E., Al-Hadeethi, Y., Zhang, X., Chen, M., Ansari, M. S., Cochis, A., & Rimondini, L. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00465 · Cited by 312
Toxicology of graphene-based nanomaterials
Lalwani, G., D'Agati, M., Khan, A. M., & Sitharaman, B. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.04.028 · Cited by 300
On the antibacterial mechanism of graphene oxide (GO) Langmuir–Blodgett films
Mangadlao, J. D., Santos, C. M., Felipe, M. J. L., de Leon, A. C. C., Rodrigues, D. F., & Advincula, R. C. (2015) · Chemical Communications · doi:10.1039/c4cc07836e · Cited by 271
Metadata
- Authors
- Hui, L., Piao, J.-G., Auletta, J., Hu, K., Zhu, Y., Meyer, T., Liu, H., & Yang, L.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-07-15
- Volume
- 6
- Issue
- 15
- Pages
- 13183-13190
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2316128619
- Cited by
- 215
- References
- 1
- FWCI
- 9.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.