The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Comparisons between Mammalian and Artificial Olfaction Based on Arrays of Carbon Black−Polymer Composite Vapor Detectors
Abstract
Arrays of broadly cross-reactive vapor sensors provide a man-made implementation of an olfactory system, in which an analyte elicits a response from many receptors and each receptor responds to a variety of analytes. Pattern recognition methods are then used to detect analytes based on the collective response of the sensor array. With the use of this architecture, arrays of chemically sensitive resistors made from composites of conductors and insulating organic polymers have been shown to robustly classify, identify, and quantify a diverse collection of organic vapors, even though no individual sensor responds selectively to a particular analyte. The properties and functioning of these arrays are inspired by advances in the understanding of biological olfaction, and in turn, evaluation of the performance of the man-made array provides suggestions regarding some of the fundamental odor detection principles of the mammalian olfactory system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A novel multigene family may encode odorant receptors: A molecular basis for odor recognition
Buck, L., & Axel, R. (1991) · Cell · doi:10.1016/0092-8674(91)90418-x · Cited by 4,987
Cited by
Optical sensor arrays for chemical sensing: the optoelectronic nose
Askim, J. R., Mahmoudi, M., & Suslick, K. S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60179j · Cited by 886
An optoelectronic nose for the detection of toxic gases
Lim, S. H., Feng, L., Kemling, J. W., Musto, C. J., & Suslick, K. S. (2009) · Nature Chemistry · doi:10.1038/nchem.360 · Cited by 476
An electronic nose in the discrimination of patients with asthma and controls
Dragonieri, S., Schot, R., Mertens, B. J. A., Le Cessie, S., Gauw, S. A., Spanevello, A., Resta, O., Willard, N. P., Vink, T. J., Rabe, K. F., et al. (2007) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2007.05.043 · Cited by 451
Semiconducting Metal Oxide Based Sensors for Selective Gas Pollutant Detection
Kanan, S. M., El-Kadri, O. M., Abu-Yousef, I. A., & Kanan, M. C. (2009) · Sensors · doi:10.3390/s91008158 · Cited by 447
An electronic nose in the discrimination of patients with non-small cell lung cancer and COPD
Dragonieri, S., Annema, J. T., Schot, R., van der Schee, M. P. C., Spanevello, A., Carratú, P., Resta, O., Rabe, K. F., & Sterk, P. J. (2009) · Lung Cancer · doi:10.1016/j.lungcan.2008.08.008 · Cited by 407
Metadata
- Authors
- Lewis, N. S.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-06-29
- Volume
- 37
- Issue
- 9
- Pages
- 663-672
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2167240759
- Cited by
- 215
- References
- 1
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.