The DOI matches its Crossref record.
Stability of High-Aspect-Ratio Micropillar Arrays against Adhesive and Capillary Forces
Abstract
High aspect-ratio (HAR) micropillar arrays have many interesting and technologically important applications. Their properties, such as large mechanical compliance, large surface area, and a topography that is well-separated from the underlying substrate, have allowed researchers to design and explore biomimetic dry adhesives, superhydrophobic, superoleophobic, and tunable wetting surfaces, mechanical sensors and actuators, and substrates for cell mechanics studies. However, the mechanical compliance and large surface area of the micropillars also make these structures susceptible to deformation by adhesive and capillary surface forces. As a result such micropillars, particularly those made from soft polymers, can prove challenging to fabricate and to use in various applications. Systematic understanding of these forces is thus critical both to assemble stable micropillar arrays and to harness these surface forces toward controlled actuation for various applications. In this Account, we review our recent studies on the stability of HAR polymeric micropillar arrays against adhesive and capillary forces. Using the replica molding method, we have successfully fabricated HAR epoxy micropillar arrays with aspect ratios up to 18. The stability of these arrays against adhesive forces is in agreement with theoretical predictions. We have also developed a new two-step replica molding method to fabricate HAR (up to 12) hydrogel micropillar arrays using monomers or monomer mixtures. By varying the monomer composition in the fabrication process, we have fabricated a series of hydrogel micropillar arrays whose elastic moduli in wet state range from less than a megapascal to more than a gigapascal, and we have used these micropillar arrays to study capillary force induced clustering behavior as a function of the modulus. As a result, we have shown that as liquid evaporates off the micropillar arrays, the pillars bend and cluster together because of a much smaller capillary meniscus interaction force while the micropillar structures are surrounded by a continuous liquid body. Previously, researchers had often attributed this clustering effect to a Laplace pressure difference because of isolated capillary bridges. Our theoretical analysis of stability against capillary force and micropillar cluster size as a function of pillar elastic modulus agrees well with our experimental observations. The fabrication approaches presented here are quite general and will enable the fabrication of tall, stable micropillar arrays in a variety of soft, responsive materials. Therefore, researchers can use these materials for various applications: sensors, responsive wetting, and biological studies. The new insights into the capillary force induced clustering of micropillar arrays could improve rational design and fabrication of micropillar arrays that are stable against capillary force. In addition, these results could help researchers better manipulate capillary force to control the assembly of micropillar arrays and actuate these structures within novel devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zhang, L., Kumar, K. S., He, H., Cai, C. J., He, X., Gao, H., Yue, S., Li, C., Seet, R. C.-S., Ren, H., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18503-8 · Cited by 574
Elasto-capillarity: deforming an elastic structure with a liquid droplet
Roman, B., & Bico, J. (2010) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/22/49/493101 · Cited by 395
Wetting of flexible fibre arrays
Duprat, C., Protière, S., Beebe, A. Y., & Stone, H. A. (2012) · Nature · doi:10.1038/nature10779 · Cited by 296
Metadata
- Authors
- Chandra, D., & Yang, S.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-06-16
- Volume
- 43
- Issue
- 8
- Pages
- 1080-1091
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2014306689
- Cited by
- 268
- References
- 0
- FWCI
- 32.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.